The ST-329BL is a permanent mount blacklight stroboscope 
array utilizing super bright, CREE high powered LED lamps. The 
ST-329BL’s LED array provides a bright, stable black light over 
a wide measurement range with a lifetime far exceeding xenon 
lit stroboscopes. The ST-329BL arrays are available in several 
standard sizes from 9.25” (235 mm) to 65” (1650 mm) in length. 
Custom sizes are available upon request. The arrays are easi-
ly mountable on production equipment.  An optional mounting 
adapter kit is available to aid in array installation. A separate con-
trol enclosure is connected with 6.5’ (2 m) cable to the array. Op-
eration is simple with the 8 button keypad and large, backlit LCD 
display.  Phase shift, flash duration, plus flash rate are all quickly 
adjustable via the control. The unit can work off user programmed 
flash frequency or from a remote sensor’s signal which will auto-
matically adjust to corresponding process fluctuations. 

The ST-329BL is designed for speed and frequency measure-
ments in the printing, packaging, textile, automotive, cable, medi-
cal industries in various applications.

ST-329BL LED Stroboscope Array

Operation Manual

SHIMPO INSTRUMENTS

Use in flammable environments is prohibited. Use in this manner may 

result in fire or explosive.

Don’t look directly into the LED light Source. This may result in eye in-

jury.

Don’t use or store in the following environments. Direct sunshine con-

densation, dust or caustic.

Do not alter, or modify of improperly. Such action may cause damage 

and void warranty.

Operate with 0-35°C (32-95°F), 35-85% RH. Use outside of this range 

may alter operation of the unit.

Case may become excessively hot when used continuously for more 

than 2 hours. Mount unit on a tripod or other fixed device.

SPECIFICATIONS

Flash Rate Range: 60 to 120,000 FPM

Accuracy: 0.01%±1 digit of F.S. @ 77° F (25°C)

Lamp Lifetime: Approximately 3~5 years depending on usage.

Display: Backlit LCD

Resolution: 60 ~12,000 FPM = 0.1 FPM; 12,001~120,000 FPM 

= 1 FPM

Flash Duration: 0.1°- 2.5°

Phase Shift: 0-359°

Power Requirement: 100-120 VAC (Optional 220 -260 VAC 

upon request). 

Input Signal: 12 V Pulse Input; M-12, 3 Pin

Input Signal Range: 60-120,000 FPM 

Input Pulse Width: Over 50 µs 

Input Signal Flash Delay: 0-999 ms; 0-359°

Temperature Limits: 32-95°F (0-35°C) 

Humidity Limits: 35 to 85% RH 

Enclosure: Control - ABS; Array - ABS window & aluminum 

frame

Mounting: Control: Magnetic mount to included bracket; Array: 

Flanges for use with 6 mm bolts. Mounting bracket kit available 

separately.

Enclosure Rating: IP65 - Control & Array

Dimensions: Length (See chart on page 6) x 6” (153 mm) x 3.5” 

(90 mm)

Approvals: CE

Warranty: 1 year

Included Accessories:  6.5’ (2 m) AC power cord, 9.8’ (3 m)

control/array connection cable (5 pin)

Operation Panel Located on Control Enclosure

POWER: Power on and off. 

MODE: Select mode of operation or Parameter Menu: Internal/

External/Parameter Settings

SET: Adjust Phase Shift; In Parameter Menu scroll through param-

eter settings, Store setting values.

x2: Multiplies the flash rate/frequency by a factor of 2.

1/2: Divides the flash rate/frequency by a factor of 2.

RATIO: Adjusts flash duration (flash pulse width) in Internal/Ex-

ternal modes.

“+”: Advance image forward 3 degrees at a time in internal mode. 

In parameter setting mode, adjusts setting values.

“-”: Retard image backwards 3 degrees at a time in internal mode. 

In parameter setting mode, adjusts setting values.

Dial: Set flash rate or frequency. CW: Increase flash rate/frequen-

cy. CCW: Decrease flash rate/frequency. (Turn dial quickly to 

drastically change value; Turn dial slowly to change value by 1 

digit.) In parameter setting mode, CW or CCW rotation chang-

es the setting value.

Dial

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание ST-329BL

Страница 1: ...ATIONS Flash Rate Range 60 to 120 000 FPM Accuracy 0 01 1 digit of F S 77 F 25 C Lamp Lifetime Approximately 3 5 years depending on usage Display Backlit LCD Resolution 60 12 000 FPM 0 1 FPM 12 001 120 000 FPM 1 FPM Flash Duration 0 1 2 5 Phase Shift 0 359 Power Requirement 100 120 VAC Optional 220 260 VAC upon request Input Signal 12 V Pulse Input M 12 3 Pin Input Signal Range 60 120 000 FPM Inpu...

Страница 2: ... adjustments rotate the dial quickly The flash rate range and resolution will be different according to the selected measur ing range One function of a stroboscope is to provide a stopped image of a rotating target when the flash rate of the stroboscope has matched the rotational speed of the target object The strobo scope will show a single image when the flash rate is set to a lesser multiple of...

Страница 3: ...ET key then enter this mode When the rotation speed of the target object and the flash rate of the ST 329BL becomes equal the phase shift function can be used to delay the flash so that the image will appear to rotate incrementally The phase shift angle can be increased or decreased 3 each time the or keys are pressed or the adjustment dial is turned CW or CCW The sub display will show the cumulat...

Страница 4: ...ed object has an advanced or lag phenomenon To adjust press the or for fine tuning change the perimeter parameters so that detected object achieves a still image In this setting process the unit will automatically save the last setting External Trigger Mode LCD Display Information The frequency of the external signal is measured each period while the latest external frequency measurement is update...

Страница 5: ...59 Delay angle decreases as the dial is rotated to the left The set tings will eventually go to 0 as the angle decreases past 359 Parameter Settings To enter parameter setting menu press MODE until the LCD dis plays P When the display shows P press the SET key to cycle between the various parameter settings available range trigger edge delay time LCD backlight Auto Shut off Initial To store the se...

Страница 6: ...If the backlight is set to on as a power saving feature it can be adjusted to automatically shut off from 1 to 1000 seconds if no keypad or dial operation has occurred The LCD backlight will turn back on with keypad or dial oper ation Factory Reset Initial To reset unit to factory values choose Yes under Initial in the parameter setting mode Then press SET Model Length LED Groups LED s ST 329BL 0 ...

Отзывы: