8).Figure. H: If the shaft does not turn freely, release it using a screwdriver inserting in the special slot. If 

this is not sufficient to solve the problem, remove the pump body, undoing the relevant mounting bolts, 

and clean it thoroughly to remove any encrustation. 

 

 

 

Figure. A                      Figure. B                     Figure. C 

 

 

 

Figure. D                      Figure. E                     Figure. F 

 

 

Figure. G                     Figure. H 

 

5). Power voltage and power  frequency must be in accordance with the nominal  values  indicated on the 

name plate. 

 

3. NOTICES ON INSTALLATION AND APPLICATION   

 

 

 

 

 

 

 

 

 

Drawing of Installation   

1). Check the electric pump includes the cable, terminal, or plug (if equipped) before the installation to see 

whether there is any damage in transit or storage. Check whether the cold  insulation resistance  exceeds 

50

MΩ.   

2).  Fix the  electric  pump properly when installation. Use  steel or hose to  connect the foot valve (if 

equipped) and electric pump inlet. Do not allow to use soft hose to avoid being flat. For self-priming pump, 

it only needs fill up with water in the housing of pump instead of full of water in the intake pipe. In order 

to keep pump reliable operation , the strainer shall be installed availably and make sure the foot valve and 

strainer to be installed at least 30cm above the water bottom to avoid foreign matters 

i.e.sand & mud) 

being sucked into electric pump chamber resulting in operation failure(See Drawing of Installation). Make 

sure that  foot valve at  intake pipe  and the one end of strainer  are  submerged  in  water  after  completing 

connection between the upper end of intake pipe and the inlet end of electric pump. The pipeline shall be 

shortened  as  much  as possible and avoid  too many  joints.  Besides,  the  suction  height  shall not exceed 

value of requirement.   

3).  Move the fan blade by screw driver,  check whether electric pump rotates freely and whether 

three–phase electric pump rotational direction  is  correct.  As  viewed  from the side of fan, clockwise 

rotation indicates electric pump rotational direction is correct. If its rotational direction is wrong, firstly cut 

off the power immediately, then swap over any two of the

 

three-phases of the electric pump. 

4). Make sure the intake pipe and its joint are sealed completely to avoid air leakage. 

 