Electric cable continuity check
1.
Disconnect all of the rear derailleur, front derailleur and junction A connectors.
2.
Connect the electric cable connector (5-wire) to the cable receptor of the checker,
connect the electric cable to the component (rear derailleur connector, front
derailleur connector or battery bracket) that you would like to check, and then press
the ENTER switch on the main checker unit.
* If the switch input is connected, the indicator will remain illuminated while the
switch is being pressed. If the switch is released, a signal will continue to be output
for a further 10 seconds.
* Check in one place at a time. If you try to check two places at once, the indicator
display will not be correct.