background image

One Holland, Irvine, California 92618, U.S.A.  Phone: +1-949-951-5003

High Tech Campus 92, 5656 AG Eindhoven, The Netherlands Phone: +31-402-612222

3-77 Oimatsu-cho, Sakai-ku, Sakai-shi, Osaka 590-8577, Japan

Please note: specifi cations are subject to change for improvement without notice. (English)  
© Feb. 2018 by Shimano Inc.  ITP

Names of parts

Outer cap

Fastening section

Gears

Sensor

LED

Control unit

Button

Charging port

Magnet

Crank arm

ANT ID

Left crank

Electric wire

Connector

Connection 

terminal

Operation

You cannot use the battery immediately after shipment.
Be sure to charge it before use.

Charging the battery

This product can be charged by using an AC adapter with a USB port or by 
connecting it to the USB connector of a PC. 
Power may no longer be supplied to the battery if the PC enters a 
hibernation or sleep state while charging.

1.  Pull at the indent in the control unit to open the cover.

Push upward

Indent

2.  Connect the charging cable as shown in the illustration. (Match the 

shapes of the charging cable and charging port when connecting.)

3.  Once charging begins, the LED lights up blue.

(Do not move the crank or cable during charging. There is a risk of the cable 
disconnecting. Reconnect the cable if it disconnects.)

LED 
(lights up blue)

4.  Once charging is complete, the LED turns off.

After charging, make sure to close the cover.

 

How to check battery level

1.  Press the button on the control unit.
2.  The LED is green or red. 

If the LED is red, fl ashing, or does not turn ON, the battery level is low. 
Charge the battery.

LED

Battery level

Green

100% - 16%

Red

15% - 3%

Red 

(fl ashing)

2% - 1%

Off

0%

LED 
(lights up 
green or red)

Note:

When the LED is lit up red, you will not be able to connect to E-TUBE 
PROJECT. 
If you continue usage in this state and the LED fl ashes red, you will be 
unable to set zero offset.

Activating the product

Press the button on the control unit or rotate the crank 2 or more times.

 

Confi rming the product has activated

• 

Activation by pressing the button

Remaining battery charge displays.

• 

Activation by rotating the crank (after connecting cycle computer)

Cadence and power display on the cycle computer when the product is 
active.

If this product does not detect motion for 5 minutes after activation, 
wireless transmission will terminate in order to save battery power.
To re-enable the wireless connection, either press the button on the 
control unit or rotate the crank 2 or more times.

Connection procedure

 

Cycle computer connection

To make a connection, the cycle computer needs to be in connection mode. 
For information on how to put the cycle computer into connection mode, 
refer to the manual for the cycle computer.

1.  Activate the product by pressing the button on the control unit or 

rotating the crank 2 or more times.

2.  Select the unit name displayed on the cycle computer screen. 

For an ANT

+TM

 connection, you can also connect by entering the fi ve 

digit ANT ID found on the reverse side of the right crank.

ANT ID

3.  This completes the connection process.

Check on the cycle computer to see if connection was successful.
If a connection cannot be made in the way described above, refer to the 
manual for your cycle computer.

 

E-TUBE PROJECT connection

Before setting up a connection, turn on Bluetooth LE on the smartphone/

tablet.

1.  Open E-TUBE PROJECT and set it to listen for Bluetooth LE signals.
2.  Press the button on the control unit.
3.  Select the unit name displayed on screen.

* To disconnect, cancel the Bluetooth LE connection from the smartphone/

tablet. (The cycle computer will exit connection mode and return to 
regular operation mode.)

To restore the Bluetooth LE Name and Passkey to their default values, 

hold down the button on the control unit for at least 3 seconds during 

battery charging. The LED will fl ash blue.

(Bluetooth LE Name: FCR9100P  Passkey: 000000)

Performing zero offset calibration

• Zero offset calibration can be performed using the control unit or the cycle 

computer.

When calibrating using the cycle computer, refer to the instruction manual 

for the cycle computer.

• It is recommended to perform zero offset calibration before riding the 

bicycle.

1.  Place the bicycle on level ground.

(At this time, do not place your feet on the pedals or apply load to the 

crank. It may not be possible to perform calibration correctly.)

2.  Position the crank arm so that it is perpendicular to the ground as in the 

illustration.

(Zero offset calibration is unaffected by whether the chain is positioned 
on the largest chainring or smallest chainring.)

3.  Press the button on the control unit until the LED lights up blue.

LED 
(lights up blue)

Button

4.  When the LED lights up blue, release the button.

The LED will begin blinking and zero offset calibration will complete.

LED 
(blinks blue)

When connected to a cycle computer via ANT

+TM

 or connected to E-TUBE 

PROJECT, "5050" will be displayed on your cycle computer, smartphone, 

or tablet once zero offset confi guration is complete. 

If some other number is displayed even if you perform zero offset 

confi guration again, contact the place of purchase or a bicycle dealer.

Specifi cations

Operating 
temperature 
range

-10°C – 50°C

Continuous 
operation 
time

300 or more hours
(for given 
temperature of 25°C)

Battery type

Lithium ion

Normal 
charging time

2.5 hours

Wireless 
specifi cation

ANT

+

TM

/Bluetooth

®

 LE

Charging 
temperature

0°C – 45°C

Frequency band

2,402 – 2,480 MHz

Maximum radio-frequency power

+4 dBm

Firmware version

4.0.3 –

Troubleshooting

If you experience any trouble using this product, please refer to the 
following.
If none of the following are applicable, or the suggested solution does not 
resolve the issue, consult with the place of purchase or a bicycle dealer.
If the power value has changed, it is possible to correct it. For details, consult 
the place of purchase.

Power does not 
display

The cycle computer may not be connected.
Follow the steps in "Connection procedure" to make a 
connection.

The battery may be out of charge.
Check remaining battery charge and charge the battery 
if the charge is low.

The left crank connector may be detached.
Remove the outer cap and check that the connector is 
connected.

Power value is 
abnormal

Zero offset calibration may not be correct.
Perform zero offset calibration referring to the section 
"Performing zero offset calibration".

Cadence does not 
display

The magnet may not be attached or may be positioned 
incorrectly.
If it is not attached or it is positioned incorrectly, 
consult with the place of purchase or a bicycle dealer.

Cadence value is 
abnormal

Another cadence sensor may be attached.
If this is the case, either remove or disable it.

LED blinks red 
during zero offset 
calibration

There may have been an issue during zero offset 
calibration.
Confi rm that the connector is connected and perform 
zero offset calibration again referring to the section 
"Performing zero offset calibration".

Charging is not 
possible

A USB hub may be connected.
Do not use a USB hub.

The charging cable may be damaged.
If charging is not possible even after trying a different 
PC or USB adapter, replace the charging cable.

Connection cannot 
be made with cycle 
computer

The cycle computer in use may not be supported.
Confi rm with the instruction manual for the cycle 
computer.

Interference may be affecting the wireless signals.
Wireless signals may be susceptible to interference in 
the following locations and conditions, preventing 
successful connection.

* Near televisions, PCs, radios, motors/engines etc., or 

inside cars and trains.

* Near railroad crossings, railway tracks, television 

transmitting stations or radar bases, etc.

* When used alongside other wireless/cordless devices 

or certain types of lighting.

Change location and reattempt connection.

About hardware reset

If an issue cannot be resolved even after referring to the troubleshooting 
section, perform a hardware reset. 

1.  Hold down the button on the control unit for 15 seconds.
2.  The hardware reset completes when the button is released.
3.  When the hardware reset is complete, the LED will light up indicating 

remaining battery charge.

After the hardware reset is complete, check operation again and if the 
issue has not been resolved, consult with the place of purchase or a 
bicycle dealer.

Отзывы: