![Shimano Steps E8000 Series Скачать руководство пользователя страница 63](http://html1.mh-extra.com/html/shimano-steps/e8000-series/e8000-series_user-manual_1257309063.webp)
61
Code
Display
preconditions
Operational restriction when
an error is being displayed
Remedy
E025
This is displayed
when a genuine
drive unit is not
connected.
This is displayed if
any of the cables
are disconnected.
No system functions will start.
Connect a genuine battery and drive unit.
Check the condition of the cables.
E033
The current
firmware doesn’t
support system
operation.
Power assistance is not
provided during riding.
Connect to E-TUBE PROJECT and update firmware
for all unit.
E043
Part of the cycle
computer’s
firmware may be
damaged.
Power assistance is not
provided during riding.
Contact the place of purchase or bicycle dealer.
Error indications (EW-EN100)
When an error occurs, the two LEDs on EW-EN100 will quickly flash red at the same time.
If this occurs, follow one of the procedures below to reset
the indication.
•
Press the battery power switch to turn the power OFF.
•
Remove the battery from the mount.
If the situation does not improve even after turning the
power back ON, consult with a distributor.
LED2
LED1