SRS0 Series
Instruction manual
ڦ
Product specification code check
Compare the specification code on the case with the following to make sure it is the product you ordered.
Ɣ
Code selection table
Item
Code Specification
1. Series
SRS1-
48 × 48 DIN size Digital Controller
SRS3
96 × 96 DIN size Digital Controller
SRS4
96 × 48 DIN size Digital Controller
SRS5
48 × 96 DIN size Digital Controller
2. Control output
Y-
Contact 240 V AC 2.5 A
P-
SSR drive voltage 12 V DC 20 mA
I-
Current 4–20 mA max. 600
ȍ
V-
Voltage 0–10 V max. 2 mA
3. Program
N None
P
1 pattern 10 steps
4. Event
1
2 points 240 V AC 1.0 A Common
5. Remarks
0 Without
9 With
ڦ
Error message
Screen
display
Problem Cause
Remedy
(H H H H )
Higher limit scaleover
(1) Break in thermocouple input wiring
(2) Break in RTD input A terminal wiring
(3) Measured input value exceeded higher limit
of measuring range by 10%.
(1) Check thermocouple input wiring for possible break. If there is nothing
wrong with wiring, replace thermocouple.
(2) Check RTD input A terminal wiring for possible break. If there is
nothing wrong with wiring, replace RTD.
(3) For voltage or current input, check the measurement signal
transmission unit.
Check if setting of measuring range code is correct for input signal.
(L L L L )
Lower limit scaleover
Measured input value fell below the lower limit
of the measuring range by 10%.
Check for measurement input wiring for reverse polarity or possible
break, etc.
(b - - - )
Break in RTD input wiring
(1) Break in B wiring
(2) Multiple break in ABB wiring
Check RTD input ABB terminal wiring for possible break. If there
is nothing wrong with wiring, replace RTD.
}
(C J H H )
Higher limit scaleover of
cold junction (CJ) of
thermocouple input
Ambient temperature has exceeded 80°C.
(1) Reduce ambient temperature to the level provided in the environment
conditions for the product.
(2) If ambient temperature has not exceeded 80°C, inspect the controller.
}
(C J L L )
Lower limit scaleover of
cold junction (CJ) of
thermocouple input
Ambient temperature has fallen below -20°C.
(1) Reduce ambient temperature to the level provided in the environment
conditions for the product.
(2) If ambient temperature has not fallen below -20°C, inspect the
controller.
ڦ
Measuring range codes
Input type
Code
Measuring range (°C)
Measuring range (°F)
*1 Thermocouple B: Accuracy guarantee is not applicable to 400°C (752°F) or below.
*2 Thermocouple K (Celsius, Fahrenheit), E, J, T, U:
Accuracy of indicated values below -100°C and -148°F is ± (1.5%FS + 1 digit).
*3 Thermocouple PL ll, U: Accuracy of indicated values is ± (1.5%FS + 1 digit + 1°C).
*4 Thermocouple K (Kelvin) accuracy temperature range:
10.0–30.0K: ±(2.0%FS + 1 digit + 1K) Provided the wire resistance is 10
ȍ
or below
31.0–70.0K: ±(1.5%FS + 1 digit + 1K) Provided the wire resistance is 10
ȍ
or below
71.0–350.0K: ±(1.0%FS + 1 digit + 1K)
*5 Thermocouple AuFe, Cr: Accuracy of indicated values is ± (1.0%FS + 1K).
*6 Thermocouple B, T: Accuracy of indicated values below these temperatures is
subject to wire resistance below 50
ȍ
:
B: 500°C (930°F)
T: -240°C (-400°F)
*7 Temperatures below -273°C (-459°F) are subject to scaleover display.
*8 With or without a decimal point is selectable for TC and Pt.
Note: Unless otherwise designated, the factory default settings are as follows:
Input range Standard/rating Measuring range
Multi-input Thermocouple
K
0–1370°C
Multi-
in
put
T
h
ermo
co
up
le
B *6
h
i
*1
0–1800°C 0–3300°F
R
hj
-50–1700°C 0–3100°F
S
hk
0–1700°C 0–3100°F
K
hl
*2
-199.9–400.0°C -300–750°F
hm
0–1370°C 0–2500°F
E
hn
*2
0–700°C 0–1300°F
J
ho
*2
-200–600°C -320–1100°F
T *6
hp
*2
-270–400°C -450–750°F
N
hq
0–1300°C 0–2300°F
PL ll *3
ih
0–1300°C 0–2300°F
WRe5-26
ii
0–2300°C 0–4200°F
U *3
ij
*2
-199.9–400.0°C -300–750°F
L
ik
0–600°C 0–1100°F
Kelvin
K
il
*4
10.0–350.0K
AuFe-Cr
im
*5
0.0–350.0K
RTD
Pt100
kl
-199.9–300.0°C -300–600°F
mV
-10–50 mV
oj
Scaling range: -1999–9999 Span: 9999 digits
ڦ
Names and functions of parts on front panel
(1) Measured value (PV) display
(2) Target set value (SV) display
(3) Action display
(4) Operating keys
Name
Function
(1) Measured value (PV) display 1) Measured value display LED (red)
• Displays current measured value (PV) on basic screen (screen 0-0).
• Displays type of parameter on each respective parameter display screen.
(2) Target set value (SV) display 2) Target value display LED (green)
• Displays current target value (SV) on basic screen (screen 0-0).
• Displays set values on each respective parameter setting screen.
(3) Action display
Displays status of controller.
• RUN: Action display LED (green)
Off:
Control halt status (STBY or RST)
On:
Running by fixed value control status (FIX)
Flashing: Running by program control status (RUN)
• OUT: Control output (green)
For output by contact or SSR drive voltage:
Off:
Output is OFF.
On:
Output is ON.
For voltage/current output:
Off when output is 0% and On when output is 100%.
In other cases, flashes at intervals of 0.5 seconds (multiples of 0.5 sec.).
• AT: Auto tuning LED (green)
Off:
Auto tuning not executed
On:
Auto tuning standby
Flashing: Auto tuning being executed
• MAN: Manual control LED (green)
Off:
Automatic control operating status
Flashing: Manual control operating status
• EV1: Event output 1 (orange)
• EV2: Event output 2 (orange)
Off:
Event output is OFF.
On:
Event output is ON.
(4) Operating keys
: Parameter key
Displays the next screen in various screen groups.
: Down key
Decrements
set
values.
: Up key
Increments
set
values.
: Entry key
Confirms
set
values.