User’s Manual
Thin/Plug-In Alarm Setter
CP3705
MCP3705-1AE
Aug., 2014
Thank you very much for employing Shimaden products.
Upon receipt of the product(s) please check the affixed label to
make sure the specifications shown conform to your requirements.
If you find any discrepancies and/or any damage on the product(s),
please contact Shimaden or its local representatives.
1. Introduction
For proper operation of the instrument(s), we recommend that you
carefully read this manual prior to operation. The manual should be
retained for future reference.
2. For safety operation
Be sure to observe the following safety clauses in your operation of
the instrument(s). Shimaden cannot undertake any responsibility
and guarantee for any damage and/or loss caused by improper
operation contrary to or neglecting these clauses.
3. Note for operation/installation
Be sure to observe the following clauses for making the best use
of the instrument(s). When the following clauses is disregarded,
the performance of the instrument(s), cannot be guaranteed.
For handling:
■
Dropping or throwing-out may cause serious damage to the
instruments.
■
Do not splash over or dip in water. For installation, select a
place where no condensation occurs.
■
Avoid operation or storage in sunny, high-temperature, dusty,
humid or vibrant environment.
On Power Supply:
Check the power rating described in the specification label placed
on the unit(s).
■
Rating 100
-
240VAC 50
-
60Hz 6.5VA max.
(Input range:85V
-
264VAC 47
-
63Hz)
■
Rating 24VDC 2.0W max. (Input range: 24VDC±10%)
For installation:
■
The instrument(s) should be installed indoors.
■
As shown in the section 9 “Mounting and Demounting”, install the
unit by Din-Rail mounting or Wall mounting.
■
Operating environmental conditions
・
Ambient temperature: -5 to +55
℃
・
Humidity: 5 to 90%RH
・
Altitude up to 2000 meters
■
Be sure that the ventilation in the chassis can be secured.
■
Be careful not to ground the minus(
-
) terminal of the power
supply.
■
The instrument should be installed as shown in the sketch below
namely, in such a position as the front panel label can be
readable in the right direction.
■
For effective heat radiation, ample space (at least 100mm)
should be allowed at the top and the bottom of the units.
Also when the units are installed in multiple stacks, the space
between each stack should be at least 130mm.
Disregard of this clause may cause fatal
harm of serious bodily injury due to or
electric shock.
Disregard of this clause may cause bodily
harm or damages to nearby objects due to
electric shock or other accidental
happenings.
■
For wiring to the terminal block, make sure that the power is
turned OFF. Otherwise, electric shock may be caused.
■
Do not break up, do not give any modification to modules, and do
not replace Power fuse at user’ side. Otherwise, fire or electric
shock may be caused.
■
In case any foreign matters(metal chip, water, liquid, etc.)
penetrate inside modules, immediately remove the power wiring
and contact Shimaden or its distributor.
■
When Main Unit is intended for use in the equipment for
transportation, communication, power-generation control and
medical care which require higher reliability and safety
characteristics. A special consideration should be taken in safety
designing for preventing malfunction of such an equipment as a
whole system.
■
Do not operate the instrument such an environment as
Flammable gases or dusts are present. Otherwise, explosion may
be caused.
■
Avoid the installation of the instruments in the vicinity of any
combustibles.
■
Because no power switch is provided on the instrument, the power
supply of the instrument cannot be turned OFF on the instrument
side. So, be sure to install a power shut-down breaker in the power
source of the instrument, and place the breaker close to the
instrument for the convenience of operation. And the breaker should
be marked as “disconnecting device” for the instruments.
■
Check out that the power supply voltage, input signal value and
terminal location conform to the published specifications of the
instrument(s). An operation under conditions outside the
specifications, heating up or burn out of the instrument(s) may
result.
■
Avoid using the instrument(s) in such a place as the ambient
temperature fluctuates rapidly to cause condensation.
■
Avoid operation or storage in such locations as corrosive gases are
present or splash of any chemical is feared.
■
The units are hot-swappable, but this operation should be avoided
as for as possible.
■
For the sake of safety, the installation and wiring should be taken
care of by fully-knowledgeable and well experienced persons.
!
WARNING
CAUTION
!
!
WARNING
CAUTION
!