User’s Manual 

Thin/Plug-In Alarm Setter 

CP3705 

MCP3705-1AE 

Aug., 2014 

 

Thank you very much for employing Shimaden products. 
Upon receipt of the product(s) please check the affixed label to 
make sure the specifications shown conform to your requirements. 
If you find any discrepancies and/or any damage on the product(s), 
please contact Shimaden or its local representatives. 
 

1. Introduction 

For proper operation of the instrument(s), we recommend that you 
carefully read this manual prior to operation. The manual should be 
retained for future reference. 
 

2. For safety operation 

Be sure to observe the following safety clauses in your operation of 
the instrument(s). Shimaden cannot undertake any responsibility 
and guarantee for any damage and/or loss caused by improper 
operation contrary to or neglecting these clauses. 

 

 

 

 

 

 

 

 

 

 

 

 

3. Note for operation/installation 

Be sure to observe the following clauses for making the best use 
of the instrument(s). When the following clauses is disregarded, 
the performance of the instrument(s), cannot be guaranteed. 

 

For handling: 

Dropping or throwing-out may cause serious damage to the 
instruments. 

Do not splash over or dip in water. For installation, select a 
place where no condensation occurs. 

Avoid operation or storage in sunny, high-temperature, dusty, 
humid or vibrant environment. 

 

On Power Supply: 

Check the power rating described in the specification label placed 
on the unit(s). 

Rating 100

240VAC 50

60Hz  6.5VA max. 

(Input range:85V

264VAC 47

63Hz) 

Rating 24VDC    2.0W max. (Input range: 24VDC±10%) 

 

For installation:

 

The instrument(s) should be installed indoors. 

As shown in the section 9 “Mounting and Demounting”, install the 
unit by Din-Rail mounting or Wall mounting.   

Operating environmental conditions 

 

Ambient temperature: -5 to +55

 

 

Humidity: 5 to 90%RH 

 

Altitude up to 2000 meters 

Be sure that the ventilation in the chassis can be secured. 

Be careful not to ground the minus(

) terminal of the power 

supply. 

The instrument should be installed as shown in the sketch below 
namely, in such a position as the front panel label can be 
readable in the right direction. 

 

For effective heat radiation, ample space (at least 100mm) 
should be allowed at the top and the bottom of the units. 
Also when the units are installed in multiple stacks, the space 
between each stack should be at least 130mm. 
 

 

 

Disregard of this clause may cause fatal 

harm of serious bodily injury due to or 

electric shock.

 

 

Disregard of this clause may cause bodily 

harm or damages to nearby objects due to

 

electric shock or other accidental 

happenings.

 

 

 

 

 

For wiring to the terminal block, make sure that the power is 

turned OFF. Otherwise, electric shock may be caused. 

Do not break up, do not give any modification to modules, and do 

not replace Power fuse at user’ side. Otherwise, fire or electric 

shock may be caused. 

In case any foreign matters(metal chip, water, liquid, etc.) 

penetrate inside modules, immediately remove the power wiring 

and contact Shimaden or its distributor. 

When Main Unit is intended for use in the equipment for 

transportation, communication, power-generation control and 

medical care which require higher reliability and safety 

characteristics. A special consideration should be taken in safety 

designing for preventing malfunction of such an equipment as a 

whole system. 

Do not operate the instrument such an environment as 

Flammable gases or dusts are present. Otherwise, explosion may 

be caused. 

Avoid the installation of the instruments in the vicinity of any 

combustibles. 

Because no power switch is provided on the instrument, the power 

supply of the instrument cannot be turned OFF on the instrument 

side. So, be sure to install a power shut-down breaker in the power 

source of the instrument, and place the breaker close to the 

instrument for the convenience of operation. And the breaker should 

be marked as “disconnecting device” for the instruments.

 

 

 

Check out that the power supply voltage, input signal value and 

terminal location conform to the published specifications of the 

instrument(s). An operation under conditions outside the 

specifications, heating up or burn out of the instrument(s) may 

result. 

Avoid using the instrument(s) in such a place as the ambient 

temperature fluctuates rapidly to cause condensation. 

Avoid operation or storage in such locations as corrosive gases are 

present or splash of any chemical is feared. 

The units are hot-swappable, but this operation should be avoided 

as for as possible. 

For the sake of safety, the installation and wiring should be taken 

care of by fully-knowledgeable and well experienced persons.

 

 

WARNING 

CAUTION 

 

 

WARNING 

CAUTION 

 