Speed and torque control parameter group 11
PARAMETER DESCRIPTION 277
5.12.6 Second motor control parameter
Realize second motor function by setting second motor control parameter and digital input terminal.
Parameter
Name
Default
Setting Range
Content
11-30
P.371
Second motor speed
control proportional
coefficient 1
100
0~2000
---
99999
11-31
P.372
Second motor speed
control integral time 1
0.30s
0~20.00s
---
99999
11-32
P.373
Second motor PI
coefficient
switch-over
frequency 1
5.00Hz
0~11-35 (P.376)Hz
---
99999
11-33
P.374
Second motor speed
control proportional
coefficient 2
100
0~2000
---
99999
11-34
P.375
Second motor speed
control integral time 2
0.30s
0~20.00s
---
99999
11-35
P.376
Second motor PI
coefficient
switch-over
frequency 2
10.00Hz
11-32(P.373)~650.00Hz
---
99999
11-36
P.377
Second motor current
control proportional
coefficient
0
0~20
---
99999
Second motor control parameter
When 00-22(P.370)≠ 99999 and RT signal is ON, second motor control parameter 11-30(P.371) ~11-36(P.377)
are valid. For second function parameter, please refer to Section 5.2.10.
Please refer to 05-22(
P.332
)~05-37(
P.347
),05-38(P.394)~05-39(P.395) for second motor parameter.
For setting, please refer to 11-00(P.320)~11-06(P.326) parameter function.