Motor parameter group 05
PARAMETER DESCRIPTION 177
5.6.3
Automatic Motor Inertia Measurement
In IM/PM with PG vector control mode, the inertia of executable load is self-learning
Parameter
Name
Default
Setting Range
Content
05-17
P.318
The motor inertia
According to
KW
0~6.5000kg.m
2
5.5K/7.5KF and under
0~65.000kg.m
2
7.5K/11KF~ 90K/110KF
0~650.00kg.m
2
110K/132KF and above
05-18
P.319
Load inertia ratio
1.0
0~600.0
---
05-19
P.391
Inertia identification
speed limit
50%
0~100%
The rated speed of the motor is
100%
05-20
P.392
Acceleration and
deceleration time of
Inertia identification
2.0s
0~20.0s
--
05-21
P.393
Operation mode of
Inertia identification
1
0
one direction rotation
1
both direction rotation
Motor inertia automatic measurement parameters
Inertia automatic measurement function is only for IM motor PG vector control (00-21(P.300)=4) or PM motor PG
vector control (00-21(P.300)=5).
When performing inertia automatic measurement function, set 05-00(P.301)=10, press
FWD
or
REV
on keypad,
the inverter will automatically calculate the following parameters: 05-18(P.319)。
The steps of automatic measurement of inertia are as follows:
start
00-21(P.300)=4
05-00(P.301)=10
Determine motor
type
PM
motor
IM
motor
Set reasonable 05-18(P.319),05-19
(P. 391),The values of 05-20(p.392)
and 05-21(p.393)
Press the forward/Reverse
key to start measuring
Finish
Y
The measurement was
successful?
Measurement fails,
operator displays "FAL"
Display will resume after
3s
N
The operator shows the
"TEnd" when the
measurement is successful
00-21(P.300)=5
05-00(P.301)=10
Setting