background image

2

Introduction

READ THIS BEFORE OPERATING YOUR UNIT

CAUTION

RISK OF ELECTRIC SHOCK 

DO NOT OPEN

CAUTION

:  TO REDUCE THE RISK OF ELECTRIC 

SHOCK, DO NOT REMOVE COVER 

(OR BACK). NO USER-SERVICEABLE 

PARTS INSIDE. REFER SERVICING TO 

QUALIFIED SERVICE PERSONNEL.

This symbol is intended to alert the user to the 

presence of uninsulated "dangerous voltage" 

within the product's enclosure that may be 

of sufficient magnitude to constitute a risk of 

electric shock to persons.

This symbol is intended to alert the user to 

the presence of important operating and 

maintenance (servicing) instructions in the 

literature accompanying the appliance.

WARNING :  TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE  

 TO RAIN OR MOISTURE.

Caution regarding installation

Note :  For heat dispersal, do not install this unit in a confined space such as a bookcase or similar enclosure.

htVmtGz{lylvGyljlp}lyGy T[YW`

vu

vmm

Note

Wall

Do not block ventilation openings or stack other equipment on the top.

FOR YOUR SAFETY

EUROPE

AUSTRALIA

220 V

-

240 V

Units shipped to Australia are designed for operation on 230 V AC only.

To ensure safe operation, the three-pin plug supplied must be inserted only into a standard three-pin 

power point which is effectively earthed through the normal household wiring. Extension cords used 

with the equipment must be three-core and be correctly wired to provide connection to earth.

Improper extension cords are a major cause of fatalities. The fact that the equipment operates 

satisfactorily does not imply that the power point is earthed and that the installation is completely 

safe. For your safety, if in any doubt about the effective earthing of the power point, consult a 

qualified electrician.

PAN-EUROPEAN UNIFIED VOLTAGE

All units are suitable for use on supplies 220-240 V AC.

CAUTION

•  Leave a space around the unit for sufficient ventilation.

•  Avoid installation in extremely hot or cold locations, or in an area that is exposed to direct sunlight or heating equipment.

•  Keep the unit free from moisture, water, and dust.

•  Do not let foreign objects in the unit.

•  The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloths, 

curtains, etc.

•  No naked flame sources, such as lighted candles, should be placed on the unit.

•  Please be care the environmental aspects of battery disposal.

•  The unit shall not be exposed to dripping or splashing for use.

•  No objects filled with liquids, such as vases, shall be placed on the unit.

•  Do not let insecticides, benzene, and thinner come in contact with the set.

•  Never disassemble or modify the unit in any way.

■ Notes on the AC power cord and the wall outlet.

•  The unit is not disconnected from the AC power source(mains) as long as it is connected to the wall outlet, even if the unit 

has been turned off.

•  To completely disconnect this product from the mains, disconnect the plug from the wall socket outlet.

•  When setting up this product, make sure that the AC outlet you are using is easily accessible.

•  Disconnect the plug from the wall outlet when not using the unit for long periods of time.

Содержание RX-4209

Страница 1: ...RX 4209 AM FM STEREO RECEIVER OPERATING INSTRUCTIONS...

Страница 2: ...of fatalities The fact that the equipment operates satisfactorily does not imply that the power point is earthed and that the installation is completely safe For your safety if in any doubt about the...

Страница 3: ...about collection and recycling of old products and batteries please contact your local municipality your waste disposal service or the point of sale where you purchased the items Information on Dispo...

Страница 4: ...ANTENNAs FM 75 ANTENNA GND AM LOOP AM Loop Antenna FM Indoor Antenna FM Outdoor Antenna AM Outdoor Antenna Change the position of the FM indoor antenna until you get the best reception of your favori...

Страница 5: ...d right and the polarity and Note For safe amplifier operation use the speakers with impedance of over 8 when you use only SPEAKER A or B terminals and use the speakers with impedance of over 16 when...

Страница 6: ...BLANCE button 10 TONE MODE button 11 ADJUST UP DOWN button 12 INPUT SELECTOR knob 13 MASTER VOLUME knob 14 REMOTE SENSOR 15 FLUORESCENT DISPLAY For details see below FLUORESCENT DISPLAY 1 Input frequ...

Страница 7: ...AKER A B buttons SLEEP button NUMERIC buttons PRESET SCAN button MONO STEREO button INPUT SELECTOR buttons MEMORY buttons MUTE button VOLUME UP DOWN buttons TUNING UP DOWN buttons PRESET UP DOWN butto...

Страница 8: ...and angles of up to 30 degrees aiming at the remote sensor htVmtGz lylvGyljlp lyGy T YW vu vmm LOADING BATTERIES 1 Remove the cover 2 Load two batteries AAA size 2x1 5V matching the polarity Remove t...

Страница 9: ...he ON STANDBY button on the front panel is pressed this unit is turned on to enter the operating mode In the standby mode if an INPUT SELECTOR button on the remote control is pressed the unit is turne...

Страница 10: ...sound level press this button again When adjusting the volume the muting effect is turned off Be sure to switch off both A and B speakers Note Be careful not to set the volume too high when using head...

Страница 11: ...laying TON CTRL if the ADJUST UP DOWN knob is rotated TON DIR will be displayed and vice versa TON DIR is displayed DIR lights up and the sound that bypasses the tone circuitry will be heard Note Extr...

Страница 12: ...UP DOWN buttons repeatedly until the right frequency has been reached Each time the BAND button is pressed the tuner is selected and then the band changes as follows FM ST FM MONO AM Frequency display...

Страница 13: ...the electricity fails or the AC input cord is disconnected for more than a week they are all cleared So you should memorize them again MEM is flickering for 5 seconds When using the NUMERIC buttons on...

Страница 14: ...o reduce the noise then FM broadcasts are reproduced in monaural sound The PRESET flickers and then receiver will start scanning the stations in the preset sequence and the tuned stations are received...

Страница 15: ...ore automatically shutting off To set the receiver to automatically turn off after the specified period of time Each time this button is pressed the sleep time changes as follows Unit minutes While op...

Страница 16: ...onnected The desired station frequency is not tuned in The antenna is in wrong position Connect an antenna Tune in the desired station frequency Move the antenna and retry tuning Preset stations canno...

Страница 17: ...ss Treble control 100 Hz 10 KHz 10 dB FM TUNER SECTION Tuning frequency range 87 5 108 0 MHz Usable sensitivity S N 30 dB 12 dBf Signal to noise ratio mono stereo 55 50 dB Total harmonic distortion 40...

Страница 18: ...RX 4209 AM FM STEREO RECEIVER Printed in China 5707 00000 870 1S...

Отзывы: