![Sherline Products WETTROTH 8100 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/sherline-products/wettroth-8100/wettroth-8100_manual_1256267006.webp)
FIGURE 7-Mounting the sensor to the belt housing
NOTE: If you have a mill with an older AC/DC motor that does not have a plastic belt guard, the
RPM sensor can be mounted in the proper position over the pulley by attaching it to the motor
mounting bracket. Locate and mark where the hole should be drilled. Remove the motor and drill
a hole through the bracket. You can use a self-tapping sheet metal screw or a bolt and nut
through the hole or you can tap the hole to match the thread of the bolt you use.
Hooking up the connecting cables
Plug the cable connector from each encoder unit into is respective port on the display unit. The
telephone type cable connectors go in with the locking tab facing up when the unit is lying on its
back. The RPM sensor cable goes into the port marked "Tach In".
Plug the power adapter into the bottom hole marked "DC In", and plug the transformer into a
115VAC (60 Hz.) source. Check to make sure all three axes are functioning. Turn on the motor
and check to see that the RPM indicator is functioning.
Initializing your display for inch or metric leadscrews
When you press the "Power" button to turn your system on, the upper right corner of the display
will read either "inch" or "metric" mode. Normally, the DRO will be set up properly when you
receive it, but there is always a possibility it could be set wrong. To set or change the system of
measurement your unit displays, follow these steps:
1. With the power off, unplug the power cable from the display unit.