Table 5.1 TZ-RD01 unify commands
NO. Instruction
Format
Note
00
Set again the stress time *00,X#
X: [0
,
3600], unit 1S, 1 is
default, 0 will disable this
function
01
Set ID
*01,X#
X:6bits, range [A-F] and [0-9]
04
Set the serial data
contain RD01’s ID
*04,X#
X:
0-No,default
1-Yes
06
Set the print mode
*06,X#
X:
0-hex (default)
1-ASCII
11
RS232 setting
*11,A,B,C,D#
A:baud,[600,128000]
115200
(
default
)
;
B:digital bits
0-8bit
(
default
),
1-9bit;
C:stop bits
0-0.5bit
,
1-1bit
(
default
),
2-1.5bit
,
3-2bit
D:parity bits,
0-none
(
default
),
1-Even,
2-Odd
13
RS232
data
mode
setting
*13,X#
X:0- active mode
(
default
)
1- Passive mode
About passive mode: need
upper computer send command
to read data.
Reading command is, AA+ ID
of RD01+ 03 (HEX)
For example:AA123403(HEX)
Query command
#D5X
X: command’s NO. For
example, *D51 can query the
NO.01
Check all configuration #DE
Check the firmware #DA