background image

 

SW8021 LoRaWAN Gateway Module Datasheet V1.0.0

 

Shenzhen Seener Wireless Technology Co., Ltd

 

            

- 6 - 

residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 
and  used  in  accordance with  the  instructions,  may  cause  harmful  interference  to radio  communications.  However, 
there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 
interference to radio or television reception, which can be determined by turning the equipment off and on, the user 
is encouraged to try to correct the interference by one or more of the following measures: 
 

Reorient or relocate the receiving antenna. 

Increase the separation between the equipment and receiver. 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. 

Consult the dealer or an experienced radio/TV technician for help. 

 
FCC Radiation Exposure Statement:   
This  equipment  complies  with  FCC  radiation  exposure  limits  set  forth  for  an  uncontrolled  environment.  This 
equipment should be installed and operated with minimum distance 20cm between the radiator& your body. 
 

OEM/Integrators Installation Manual   

List of applicable FCC rules 

This module has been tested and found to comply with part 15.247 requirements for 

Modular Approval. 

Summarize the specific operational use conditions 

This module can be applied in household electrical 

appliances as well as TV and IP camera. The input voltage to the module should be nominally 3.0

3.6 VDC, typical 

value 3.3VDC and the ambient temperature of the module   
should not exceed 85

.   

Limited module procedures

   

N/A   

Trace antenna designs

   

N/A   

Antennas   

The module of SW8021-U 

has a unique antenna port arrangement for LoRa, which was employed the dipole antenna 

with maximum gain is 1dBi. If used different type or higher than 1dBi of antenna, that requires the 

submission of a 

Class II permissive change or new application.

 

 

Label and compliance information 

When the module is installed in the host device, the FCC ID label must be 

visible through a window on the final device or it must be visible when an access panel, door or cover is easily re

moved. If not, a second label must be placed   
on the outside of the final device that contains the following text: Contains Transmitter Module   
FCC ID:

 

2A4BH-SW8021, the FCC ID can be used only when all FCC ID compliance requirements are met. 

 

Information on test modes and additional testing requirements 

a)

 

The  modular  transmitter  has  been  fully  tested  by  the  module  grantee  on  the  required  number  of  channels,   
modulation  types,  and  modes,  it  should  not  be  necessary  for  the  host  installer  to  re

test  all  the  available   

transmitter  modes  or  settings.  It  is  recommended  that  the  host  product  manufacturer,  installing  the  modular   
transmitter,  perform  some  investigative  measurements  to  confirm  that  the  resulting  composite  system  does   
not  exceed  the  spurious  emissions  limits  or  band  edge  limits  (e.g.,  where  a  different  antenna  may  be  causing   

Содержание SW8021

Страница 1: ...LoRaWAN Gateway Module Datasheet Version V1 0 0 Data 2021 10 15 Gateway module series SW8021 LoRaWAN Gateway Module Datasheet ...

Страница 2: ...SW8021 LoRaWAN Gateway Module Datasheet V1 0 0 Shenzhen Seener Wireless Technology Co Ltd Document Information Version Time Description Remark V1 0 0 2021 10 15 Preliminary version Ming ...

Страница 3: ...ritten permission all commercial use of the files from Seener are forbidden such as copy distribute reproduce the files etc but non commercial purpose downloaded or printed by individual are welcome Disclaimer Shenzhen Seener Wireless Technology Co Ltd reserves the right to change modify or improve the document and product described herein Its contents are subject to change without notice These in...

Страница 4: ...ifications 1 2 2 Electric specifications 2 2 3 Absolute maximum rating 2 2 4 Operating conditions 3 2 5 Operating conditions 3 2 6 RF Characteristics 3 2 7 Electrical Requirements 4 3 Typical Hardware Connections 4 3 1 Physical dimensions 4 3 2 Interfaces 4 3 2 1 SPI Interface 4 3 2 2 Power pins 5 3 2 3 RF connection 5 3 2 4 RESET pin 5 4 Reliability Test and Approves 5 5 Package 7 6 Contact Us 7 ...

Страница 5: ...ackets at 8 different spreading factors and 8 channels with continuous demodulation of up to 16 packets It targets Internet of Things IoT applications covering up to 500 nodes per square kilometer in an environment with moderate interference Table 1 1 Product model list 1 2 Product features Multichannel eight 8 programmable parallel demodulation paths SPI Interface The SPI interface gives access t...

Страница 6: ...vice These are stress ratings only and operation of the device at these or at any other conditions above those given in the Characteristics sections of the specification is not implied Exposure to these limits for extended periods may affect device reliability 2 3 Absolute maximum rating Table2 3 absolute maximum rating Stressing the device beyond the Absolute Maximum Ratings may cause permanent d...

Страница 7: ...imum limit to switch on the module Table2 5 1 Operating power supply range Operating beyond the specified operating conditions can affect device reliability 2 5 2 Power Consumption Mode Condition Min Typical Max Active Mode TX The power of TX channel is 15 90dBm and 3 3V supply 500mA 520mA 550mA Active Mode RX TX disabled and RX enabled 70mA 85mA 105mA Table2 5 2 Working current 2 6 RF Characteris...

Страница 8: ...nctionality of the device is guaranteed Where application information is given it is advisory only and does not form part of the specification 3 Typical Hardware Connections 3 1 Physical dimensions Figure 3 1 dimensions 3 2 Interfaces Reference circuit design shows the typical hardware connections for the module Interfacing to the module requires connecting to the signals provided on the SW8021 mP...

Страница 9: ...roves Tests for product family qualifications are according to ISO 16750 Road vehicles Environmental conditions and testing for electrical and electronic equipment and appropriate standards Products marked with this lead free symbol on the product label comply with the Directive 2002 95 EC and Directive 2011 65 EU of the European Parliament and the Council on the Restriction of Use of certain Haza...

Страница 10: ...ied in household electrical appliances as well as TV and IP camera The input voltage to the module should be nominally 3 0 3 6 VDC typical value 3 3VDC and the ambient temperature of the module should not exceed 85 Limited module procedures N A Trace antenna designs N A Antennas The module of SW8021 U has a unique antenna port arrangement for LoRa which was employed the dipole antenna with maximum...

Страница 11: ...e FCC requirements by a technical assessment or evaluation to the FCC rules including the transmitter operation and should refer to guidance in KDB 996369 For host products with certified modular transmitter the frequency range of investigation of the composite system is specified by rule in Sections 15 33 a 1 through a 3 or the range applicable to the digital device as shown in Section 15 33 b 1 ...