Страница 2: ...splay screen support standard class II network management transponder 2 Features Optimized circuit design SMT process production optimized signal path make the photoelectric signal transmission more smooth SCM control working status LCD displays the parameters convenience and intuitive operation and stable performance Excellent AGC characteristic keep stable output level in the received optical po...

Страница 3: ...Output Impedance Ω 75 Adjustment Range of Output Level dB 10 Normal mode turn on the optical AGC function 30 Normal mode turn off the optical AGC function adopt MGC control 30 RFOG burst mode The Accuracy of RF Test Port dB 20 1 Isolation between channels dB 65 RF connector type Female F connector or male F connector NPR Dynamic Range dB 15 NPR 30 dB Use DFB laser 10 NPR 30 dB Use FP laser Supply ...

Страница 4: ...mal AGC MGC 1 Normal is the general working mode AGC or MGC optional 2 Select AGC turn on the optical AGC function the output level will not vary with the change of received optical power its adjustable range is 10dB 3 Select MGC turn off the optical AGC function the output level will vary with the change of received optical power its adjustable range is 30dB RF OutPut SWx ON OFF Under the Normal ...

Страница 5: ...se the parameter value 6 1 Main menu Displayed parameters Comment OP OR124RJ Boot display machine model OP OR124RJ 1 Disp set Module 1 Press Enter Menu 1 display set the first way return module 2 Disp set Module 2 Press Enter Menu 2 display set the second way return module 3 Disp set Module 3 Press Enter Menu 3 display set the third way return module 4 Disp set Module 4 Press Enter Menu 4 display ...

Страница 6: ...le Two modes optional Normal common mode RFOG burst mode Set AGC MGC 1 MGC Set the ATT mode of the first way return module Two modes optional AGC turn on the optical AGC mode MGC turn off the optical AGC mode manual adjustment This menu is hidden under the RFOG mode Set RF OutPut SW 1 OFF Set the RF output switch of the first way return module ON turn on OFF turn off This menu is hidden under the ...

Страница 7: ...le Two modes optional Normal common mode RFOG burst mode Set AGC MGC 2 MGC Set the ATT mode of the second way return module Two modes optional AGC turn on the optical AGC mode MGC turn off the optical AGC mode manual adjustment This menu is hidden under the RFOG mode Set RF OutPut SW 2 OFF Set the RF output switch of the second way return module ON turn on OFF turn off This menu is hidden under th...

Страница 8: ...le Two modes optional Normal common mode RFOG burst mode Set AGC MGC 3 MGC Set the ATT mode of the third way return module Two modes optional AGC turn on the optical AGC mode MGC turn off the optical AGC mode manual adjustment This menu is hidden under the RFOG mode Set RF OutPut SW 3 OFF Set the RF output switch of the third way return module ON turn on OFF turn off This menu is hidden under the ...

Страница 9: ...le Two modes optional Normal common mode RFOG burst mode Set AGC MGC 4 MGC Set the ATT mode of the fourth way return module Two modes optional AGC turn on the optical AGC mode MGC turn off the optical AGC mode manual adjustment This menu is hidden under the RFOG mode Set RF OutPut SW 4 OFF Set the RF output switch of the fourth way return module ON turn on OFF turn off This menu is hidden under th...

Страница 10: ... OP OR124RJ Four way Return Path Optical Receiver 6 6 The setting menu of Ethernet parameters Displayed parameters Comment Remark Set IP Addr 192 168 1 168 Set IP address Can change Set Mark Addr 255 255 255 0 Set subnet mask Can change Set Gateway 192 168 1 1 Set gateway Can change Set Trap Addr1 192 168 1 24 Set trap1 address Can change Set Trap Addr2 192 168 1 25 Set trap2 address Can change ...

Страница 11: ...ur way mixed 20dB test port 7 2 Rear Panel 1 Reserved four way mixed RF output 2 20dB test port 1 3 RF output 1 4 20dB test port 2 5 RF output 2 6 20dB test port 3 7 RF output 3 8 20dB test port 4 9 RF output 4 10 Fan outlet 11 Network management interface 12 AC220V power input 13 Fuse 14 Power switch 15 AC220V power input 16 Fuse 17 Power switch 18 Grounding stud 19 Reserved postposition four way...

Страница 12: ...192 168 1 168 default gateway is 192 168 1 1 default subnet mask is 255 255 255 0 2 Connect the computer and responder can be direct connected and change the computer IP to 192 168 1 XXX XXX is any number from 0 to 255 except 168 start upper computer network management software then search the device and log in 3 Right click device icon and choose modify the device IP 4 Enter new IP address gatewa...

Страница 13: ...dical degrease alcohol cotton still need to wait 1 2 minutes after wash let the connector surface dry in the air 3 The cleaned optical fiber active connector should be connected to optical power meter to measure output optical power to affirm whether it has been cleaned up 4 When connect the cleaned optical fiber active connector back to adapter should notice to make the force appropriate to avoid...

Страница 14: ...ons we will responsible maintenance but ask suitable material cost 2 When the equipment breaks down immediately contact local distributor or directly call our technical support hotline 86 755 26400198 3 The site maintenance of the fault equipment must be operated by professional technicians to avoid worse damage Special notice If the equipment has been maintained by users we will not responsible f...