3
-15
3.4
Automatic power off /sleep mode
Step 1 Enable the Auto power off function, choose how long you want it to automatically power off.
Graph 3-1 Automatic power off parameter configuration tag
a)
Without extended power supply: if there is no data transmitting via Bluetooth or serial interface during Auto
Power off period, the device will be powered off automatically.
b)
With extended power supply: if there is no data transmitting via Bluetooth or serial interface during Auto
Power off period, the device enters sleep mode.
c)
The device would automatically power off when battery’s voltage is lower than 3.2V.
The power on/power off status described by this section defaults battery having been connected, and power supply
only through adapter without connecting battery is categorized as unregulated operation, out of the discussion.
--- End
Step 2: Configure Automatic power off configuration, and parameter description is as shown in table 3-1.
Table 3-1 Automatic power off configuration parameter descriptions
Parameter name
Parameter description
Automatic power
off
time
(Auto
Power off)
if there is no data transmitting via Bluetooth or serial interface during Auto
Power off period, the device enters sleep status
Supported configurations: NEVER, 5min, 10min, 15min, 20min, 30min,
wherein Never means never automatic power off