![SHENZHEN FLYING INDUSTRY DEVELOPMENT S2PU-AC380-ANT3 Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/shenzhen-flying-industry-development/s2pu-ac380-ant3/s2pu-ac380-ant3_quick-start-manual_1255898002.webp)
SHENZHEN FLYING INDUSTRY DEVELOPMENT CO.,LTD
http://www.carymart.com E-Mail: [email protected]
Release button 1: The relay 1 is deactivated, and the contactor 1 is disconnected, the equipment 1 stops working.
Press and hold button 2 of the transmitter: The relay 2 is activated, and the contactor 2 is connected, the equipment 2 works.
Release button 2: The relay 2 is deactivated, and the contactor 2 is disconnected, the equipment 2 stops working.
3) Setting Interlocking mode: Turn on the dip switch 1, and turn off the dip switch 2.
Mode Interlocking (working with transmitter CG-3 or CB-3-2): Press -> On; Press another button -> Off.
Press button
▼
of the transmitter: The relay 1 is deactivated, and the contactor 1 is connected, the equipment 1 works.
Press button
■
of the transmitter: The relay 1 is deactivated, and the contactor 1 is disconnected, the equipment 1 stops working.
Press button
▲
of the transmitter: The relay 2 is activated, and the contactor 2 is connected, the equipment 2 works.
Press button
■
of the transmitter: The relay 2 is deactivated, and the contactor 2 is disconnected, the equipment 2 stops working.
4) Setting Mixed mode (Mom Self-locking): Turn on the dip switch 1 and 2.
Mode Momentary for channel 1 (working with transmitter CG-2): Press and hold -> On; Release -> Off.
Press and hold button 1 of the transmitter: The relay 1 is deactivated, and the contactor 1 is connected, the equipment 1 works.
Release button 1: The relay 1 is deactivated, and the contactor 1 is disconnected, the equipment 1 stops working.
Mode Self-locking for channel 2 (working with transmitter CG-2): Press -> On; Press again -> Off.
Press button 2 of the transmitter: The relay 2 is activated, and the contactor 2 is connected, the equipment 2 works.
Press button 2 again: The relay 2 is deactivated, and the contactor 2 is disconnected, the equipment 2 stops working.
Manual buttons:
Press manual button
▼
of the receiver: The relay 1 is deactivated, and the contactor 1 is connected, the equipment 1 works.
Press manual button
■
of the receiver: The relay 1 is deactivated, and the contactor 1 is disconnected, the equipment 1 stops working.
Press manual button
▲
of the receiver: The relay 2 is activated, and the contactor 2 is connected, the equipment 2 works.
Press manual button
■
of the receiver: The relay 2 is deactivated, and the contactor 2 is disconnected, the equipment 2 stops working.
How to pair the transmitter to the receiver:
1) Press the learning button of the receiver, signal LED on the receiver is on, the receiver enters into status of LEARNING.
2) Press any button on transmitter within 5 seconds, if signal LED flashes 2 times then turns off, it means learning is successful.
3) The receiver can learn several transmitters with different codes.
Delete all transmitters:
We have learned the transmitter to the receiver. If you don’t want the receiver to work with the transmitter, you can delete all codes of the transmitters
which are stored in the receiver.
Operation: Pressing the learning buttons of the receiver for 6~7 seconds until the signal LED on the receiver flashes 3 times, then release the
learning button. That means all stored codes have been deleted successfully.