background image

Notes:

10

Содержание SR1555

Страница 1: ...Assembly Instructions Shelter type SR1555 SR1555 02 09052017 S4L www shelters4less co uk sales shelters4less co uk 0800 160 1002 ...

Страница 2: ...1 2 3 4 10 12 13 12 14 11 5 9 6 8 7 15 2 Exploded View of Shelter Tools required Drill Screwdriver Mallet Hack saw Tools included Wrench Torx bit ...

Страница 3: ...o 2195 7 9 RB1 Bracket 2060x40x40 8 10 R2 Rafter 106x110x80 4 11 SS Sealing Strip 110x46 3 ROLLS 12 PCE2 Roof Panel 2205x1050 2 13 PCC2 Roof Panel 2205x1030 1 14 RC2 Roof Strip 2205 4 15 2MD Roof Edge Trim Trim To Fit 5 16 EC40 Plastic End Cap 40x40 11 Fittings Bolt set M10 T25 T50 BTANCM12100 M10 x 60mm Nut Washer 25 mm Tech screw 50 mm Tech screw Black Caps M10 12 x 100 mm Concrete Bolt Pack A B...

Страница 4: ...K CORRECT ALIGNMENT Please note 50mm Tec Screws are for roof panels only CB1 JF1 S1 CB1 CB1 CB1 Ensure correct corner alignment Step 1 Assemble S1 frames to make up the main structure using CB1 brackets for the Corners and JF1 brackets for the straight joints 4 ...

Страница 5: ... post using a JF1 bracket then use two JF1 brackets to attach S3 frame The ST5 tie bar is mounted using a CB1 and a JF1 bracket Make sure the structure is square then move the shelter to its final location before using the FT1 foot brackets to secure it to the ground 5 ...

Страница 6: ...R2 RB1 1035 1035 1035 ENSURE CORRECT ALIGNMENT OF RAFTERS RB1 R1 Step 3 Attach R2 rafters using RB2 brackets 6 SIDE VIEW ...

Страница 7: ... Step 4 Stick sealing strips SS to the rafters Align the PCE2 roof panels with the outer roof rafters and equaly space the PCC2 panel in the middle Apply more sealing strips to the top of the roof panels directly above the first strips 7 ...

Страница 8: ...2MD 2RC 2MD RC2 Step 5 Screw down the RC2 directly into the rafter strips as shown below using 50mm Tech screws Then apply the 2MD edge trim to the bottom edges of the roof panels 8 ...

Страница 9: ...O FOOT HOLE CENTERS 1044 50 1035 1035 1044 50 1035 1084 50 477 1531 50 995 1035 3145 11 PLAN VIEW OVERALL DIMENSIONS AND GROUND FIXING POSITIONS Suggested size for concrete base 200mm oversized on all 4 sides ...

Страница 10: ...Notes 9 ...

Страница 11: ...Notes 10 ...

Страница 12: ...ularly with soapy water Ensure all fittings are tight for example after a big storm Touch up any exposed metal should it get scratched CONTACT DETAILS Email Sales shelter4less co uk Web www shelters4less co uk Tel 0800 160 1002 Shelters4Less Unit 3 2 Landsdowne Crescent Bournemouth BH1 1SA All Parts and Fixings checked by Print Name Signature ...

Отзывы: