Basic Frame Assembly

NOTE: FRAME EXTENSION kIT

22'x20'x13' is the base frame dimension. Your model may have more middle ribs than shown in the illustration on pg.2. 

You will receive one extra rib for every extra 4 ft. of building length that you purchase. The basic frame assembly will 

remain the same. The cover will be the correct size for the length of the building

1. PloTTInG THe FRAme:

2. ASSemBle end RIBS

3. ASSemBle mIddle RIBS

Before building your shelter, you should choose a flat area on your prop-

erty and plot your shelter.

1.  Stake out the area for the shelter in the desired spot.  The width of the 

area should be at least equal to the width of the shelter and the length 

should be equal to the length (“L”) of the shelter 

Fig. 1

.

2.To be sure the staked area is square tie a rope diagonally from corner to 

corner.

3.Measure from where the two ropes intersect each other to all 4 corners.  

This measurement should be the same.  If they are not equal the stakes 

need to be adjusted until the width, length and inside measurements are 

correct.

Assemble end ribs as shown in 

Fig. 2

.  Securely

fasten all of the joints with the hardware indicated.

Assemble middle ribs as shown in 

Fig. 3

.  Securely

fasten all of the joints with the hardware indicated.

Use #11131

5/16" x 2 3/4" L

Bolts

Use #11131

5/16" x 2 3/4" L

Bolts

 

A

B

BUILDING 

LENGTH 

22 ft.

WIDTH

Fig.1

Fig.2

Fig.3

11016

11019

11016

11019

04551

04551

04551

04551

11013

11013

11013

11013

11068

11068

11068

11068

11136

11135

11270

11270

4. ASSemBle WInd BRAceS

Assemble all of the wind braces as shown in 

Fig. 4

.  

Securely fasten the joints with the hardware indicated.

Fig. 4

11193

11095

800053

00648

00690

00690

Содержание 107153

Страница 1: ...ze of your building Allow approximately 15 minutes for every foot in building length Please read instructions COMPLETELY before assembly This shelter MUST be securely anchored THIS IS A TEMPORARY STRU...

Страница 2: ...terLogic LLC Shelters offer storage and protection from damage caused by sun light rain tree sap animal bird excrement and light snow Please anchor this ShelterLogic LLC structure properly See manual...

Страница 3: ...135 14 11107 2 11136 15 11270 3 11013 16 11130 4 11016 17 11131 5 11019 18 800454 6 11068 19 11133 7 11095 20 11134 8 11101 21 00648 9 11102 22 11093 10 11103 23 04551 11 11104 24 800053 12 11105 25 8...

Страница 4: ...f the shelter Fig 1 2 To be sure the staked area is square tie a rope diagonally from corner to corner 3 Measure from where the two ropes intersect each other to all 4 corners This measurement should...

Страница 5: ...ctions that do not use a wind brace use a 4 1 8 bolt 800454 800372 00690 800454 6 Install Wind Braces Attach wind brace between the end rib and the first middle rib as shown in Fig 6 Use 11134 Bolt Bo...

Страница 6: ...r and around the frame as indicated in Fig 10 Secure the cable with the clamp s provided Fig 10 End Rib Anchors Middle Rib Anchors 11105 8 Sliding cover rail assembly A Place a Cover Rail Pipe 11105 b...

Страница 7: ...the cross rail and wind brace Replace the nut and tighten Repeat this on the other side D At the bottom where the webbing exits the pocket on each side of end panel pull webbing to remove the slack Be...

Страница 8: ...le rib from the rear so that it is inserted in the pipe pocket on both ends of the pipe but the center of the pipe is exposed For long buildings it may be necessary to use additional pipes in the midd...

Страница 9: ...tchet so that the webbing overlaps itself D Disassemble cover rails and slide through fabric pockets at each leg and reattach with clamps to each leg Repeat this on other side Push down on cover rails...

Отзывы: