background image

1

SHELTER OUTDOOR FURNACE MANUAL

MODEL: SF4200

EPA Certified to the Warm Air Furnace NSPS requirements, for sale May 2017 through May 2020.

SAVE THESE INSTRUCTIONS

Congratulations!  You have selected the finest quality outdoor wood burning furnace, manufactured with pride in the USA.  

Please take a few moments to carefully read the owner’s manual.  By taking the time to familiarize yourself with your new 

Shelter Furnace, you will be able to look forward to years of trouble-free, dependable service.

Installation:

 

•   First, check local codes.  The installation must comply with all local rulings and requirements.

 

•   This furnace is an outdoor hot air furnace and must not be altered in any way.

 

•   This furnace requires a back-up electric generator, 2000 watts minimum, in case of power failure.

 

•   Always have a properly installed and functioning smoke detector installed in your home.

 

•   To prevent accidental injury, do not allow anyone who is unfamiliar with the furnace to operate it.

 

•   Spend time familiarizing yourself with your Shelter Furnace, especially the different settings and the   

  

effects they have on burn patterns.  It is impossible to predict how each setting will affect your furnace, due to   

 

  variations in conditions, fuels, and temperatures.

 

•   When making plans to install your outdoor furnace, the first thing you need to think about is the placement of the        

                  unit.  Although you can install the Shelter Furnace up to 30 feet from the home, a much shorter distance is                         

 

     recommended to provide better airflow.  The furnace has been tested for clearance of 12 inches from the home;                      

                  this would give maximum airflow and provide the highest efficiency.

Transportation Damage

Every effort has been made to ensure that your Shelter Furnace will arrive in perfect condition.  Any visible damage should be 

noted on the freight bill at the time of delivery.  If upon unpacking your furnace, you find damage has occurred during transit, 

notify your dealer immediately.  Your dealer will advise you what actions must be taken to correct the problem.

Disclaimer Notice

The listed BTU rating of your new Shelter Furnace was obtained using laboratory calculations. The actual BTU output you 

experience may vary somewhat depending on the type, condition, and moisture content of the fuel used, damper 

adjustment, chimney type and other variables.  Therefore, the manufacturer disclaims any guarantee as to the BTU output 

or capacity of your furnace.  Shelter Furnace disclaims any responsibility for the following: installation of a furnace that has 

been altered or modified in any way; installation of the furnace other than as instructed in this manual; installation and or 

use of any component or part not approved by Shelter Furnace for use on this furnace.  Be sure to complete and return your 

warranty card within 30 days of purchase in order to activate warranty coverage on your furnace.

Manufacturer’s Notice

Please be advised that periodic changes are made to improve the furnaces.  Therefore the information in this manual may not 

be completely applicable to your Shelter Furnace.  Please refer to markings on the appliance for additional information.

THIS IS AN OUTDOOR WOOD BURNING FURNACE ONLY AND SHOULD NOT 

BE ALTERED IN ANY WAY.

Содержание SF4200

Страница 1: ...DOOR FURNACE MODEL SF4200 Manufactured by Shelter Furnace 10950 Linpage Place Saint Louis MO 63132 1 800 875 4788 MADE IN USA October 2016 Tested to UL391 and CSA B366 1 2011 and B415 1 2010 Standards...

Страница 2: ......

Страница 3: ...tput Wood that is properly cut and stored to dry will produce more BTUs and higher heat output than wood that has a higher moisture content Wood with higher moisture content will create creosote in th...

Страница 4: ...rnace has been tested for clearance of 12 inches from the home this would give maximum airflow and provide the highest efficiency Transportation Damage Every effort has been made to ensure that your S...

Страница 5: ...ion 11 General Operation 12 FIRST FIRE 12 LOADING WOOD 12 Fuel Recommendations 13 Disposal of Ashes 13 Heat Dump and Fuse Link System 14 Draft Blower 14 CREOSOTE FORMATION 14 CREOSOTE PREVENTION 15 Po...

Страница 6: ...of these features as standard equipment offering you the most efficient durable and affordable appliance possible Abnormally cold weather could reduce the burn time Your Shelter Furnace is designed to...

Страница 7: ...ot interchange with other brands A tube of high temp silicone caulk is included with your furnace Before using the silicone to install the anchor plate to the top of your Shelter Furnace ensure the ch...

Страница 8: ...1 800 875 4788 THIS UNIT IS NOT TO BE CONNECTED TO A CHIMNEY FLUE THAT SERVES ANOTHER APPLIANCE INSTALLING THE ANCHOR PLATE Note Check with your dealer for the anchor plate that connects to Class A HT...

Страница 9: ...up the chimney the length of the measurement increases Once this measurement reaches 10 feet this height on the chimney is your base height The chimney must be 2 feet taller than the base height If th...

Страница 10: ...minimum Use Class A HT 2100 All Fuel 6 Inch Chimney for your Shelter Furnace Never use galvanized pipe in your flue connection Inspect the flue periodically for structural integrity Clean the flue reg...

Страница 11: ...od or particleboard The prohibition against burning these materials does not prohibit the use of fire starters made from paper cardboard saw dust wax and similar substances for the purpose of starting...

Страница 12: ...air duct vent as well as the vent for the cold air return The cold air return is an integral part of the system and must be used when installing the furnace Failure to use cold air return will pressur...

Страница 13: ...ted insulated flexible hot air duct to connect the central duct system for the home When using flexible duct inside the home it must be pulled tight with no offsets or elbows to prevent turbulence and...

Страница 14: ...rn Ideally locate each at opposite ends of the home If you don t the air will not flow evenly throughout the home This method will work well on homes built on concrete slabs and help create a good air...

Страница 15: ...operating at full capacity The new steel and metal components of the furnace have a protective coating or paint on the surface which could produce an odor during the break in period Adequate ventilat...

Страница 16: ...into a metal container with a tight fitting lid The closed container of ashes should be placed on a non combustible floor or on the ground well away from all combustible materials pending final dispo...

Страница 17: ...motor turns on and supplies fresh air into the firebox producing a hotter fire which in turn provides more heat in the heat chamber The heat is then sent through the duct system throughout your home W...

Страница 18: ...lammable liquids inappropriate materials Maintaining Your Furnace At the beginning of each heating season take time to thoroughly check your furnace and chimney system Make sure there are no leaks whe...

Страница 19: ...e in any way CAUTION HOT SURFACES KEEP CHILDREN AWAY DO NOT TOUCH DURING OPERATION CAUTION INSPECT FLUE PIPES JOINTS AND SEALS REGULARLY TO ENSURE THAT SMOKE AND FLUE GASES ARE NOT DRAWING INTO AND AR...

Страница 20: ...lower and motor pulleys may be changed but the electrical current flowing through the motor cannot exceed the nameplate rating On a direct drive system the motor should not be changed however the spee...

Страница 21: ...1 4 PARTS LIST DESCRIPTION QTY ITEM BLOWER WHEEL 1 1 BLOWER HOUSING 1 2 MOTOR CAPACITOR 1 3 BLOWER MOTOR 1 4 2 1 3 4 1 2 2 3 2b 5 4b 5 4 SF4200 PARTS LIST ITEM QTY PART DESCRIPTION 1 1 FC000 ROLLER GR...

Страница 22: ...B FAN LIMIT CONTROL WALL THERMOSTAT 120V AC 24V AC TRANSFORMER RELAY DRAFT BLOWER MOTOR BLOWER MOTOR BLACK 120V AC POWER SUPPLY WHITE BLACK GREEN BLACK WHITE YELLOW RED RED RED YELLOW BLACK ORANGE WIR...

Страница 23: ...rnace not providing enough heat Furnace size is inadequate for your home 2 Open slide cover to an opening of approximately 3 8 inches Completely avoid using if at all possible If circumstances necessi...

Страница 24: ...t accumulation surrounding air registers in the home Possible Causes Remedies Furnace is not connected to return air duct and is disbursing dirt throughout home Connect to return air duct system Insta...

Страница 25: ...gases which causes them to condense as creosote on the inside of the flue Using uninsulated stove pipe for the chimney Problem Smoke from the fire chamber is puffing back through the forced draft mot...

Страница 26: ...turing process Firing the furnace has raised the tempera ture of the fire box to a level that is sufficient to vaporize the residue The odor should disappear after a few hours of usage Possible Causes...

Страница 27: ...nction containing gases within the fire chamber Possible Causes Remedies 17 Insufficient natural draft or an obstruction in the flue system See 8 9 and 16 Fire chamber filled to capacity with unburned...

Страница 28: ...xcluded from this warranty In order to exercise the aforementioned warranty a certified professional must determine the appliance part to be defective He or she must submit a written statement to Shel...

Страница 29: ......

Отзывы: