10
blower cannot be changed. This equipment should be installed, acceptable to regulatory authority, by experienced licensed personnel.
The installation should comply with requirements of CAN/CSA-B365, and changes to the installation should comply with CSA-B139 (for
oil-fired), C22.1 (for electric), or CAN/CGA-B149.1 or CAN/CGA-B149.2 (for gas-fired).
IMPORTANT: FOR TECHNICAL SUPPORT OR CUSTOMER SERVICE
ISSUES, DO NOT RETURN TO THE STORE (THE STORE DOES NOT HAVE
REPLACEMENT PARTS), CALL SHELTER FURNACE AT 1-800-875-4788.
BURN WOOD AND COAL ONLY!
General
Operation
NOTE: Always pull the bypass rod all the way out before opening the fuel door.
Types of Wood to Use:
We advise using only dry, seasoned hardwoods in your Shelter Furnace rather than high resin woods such as pine. Firewood should be
cut at least one full season prior to the time of its intended use, for optimum heat output. Firewood should be stacked to provide a free
flow of air between the logs, thus allowing more rapid seasoning of the wood. If wood is stored outdoors, it should be completely covered
year round to protect it from moisture and exposure to the elements.
FUEL RECOMMENDATIONS: (Log size by model)
• SF2626 – 22 inch maximum log length
• SF2631 – 28 inch maximum log length
• SF2639 – 34 inch maximum log length
Use extreme caution when opening the door during operation, temperatures can exceed 300°F. Always pull the bypass rod all the way
out before opening the fuel door. Wait at least 10 seconds after releasing the latch, and then proceed to the fully open position. Opening
the door in this manner is designed to eliminate the possibility of gaseous ignition. Heat resistant gloves are recommended when
opening the fuel door, regulating the spin draft, or emptying the ash pan.
CAUTION: HOT SURFACES. KEEP CHILDREN AWAY. DO NOT TOUCH DURING OPERATION.
CAUTION:
• INSPECT FLUE PIPES, JOINTS AND SEALS REGULARLY TO ENSURE THAT SMOKE AND FLUE GASES ARE
NOT DRAWING INTO, AND ARE NOT BEING CIRCULATED BY THE AIR-CIRCULATION SYSTEM.
• CLEANING OF THE HEAT EXCHANGER, FLUE PIPE, CHIMNEY AND DRAFT INDUCER (IF USED), IS
ESPECIALLY IMPORTANT AT THE END OF THE HEATING SEASON TO MINIMIZE CORROSION DURING THE
SUMMER MONTHS CAUSED BY THE ACCUMULATED ASH.
• Never use chemicals or gasoline to start or maintain your fire.
• Do not burn oil, garbage, trash, plastic, or any fuel other than wood or coal in your furnace. Doing so will void the
warranty.
• DO NOT operate your furnace with the fuel bypass rod open; the handle must be pushed all the way in (except
when refueling).
• DO NOT leave the ash pan inside your furnace during operation.
WARNING: – RISK OF FIRE
• DO NOT operate with flue draft exceeding .08 water column inches (19.9 Pa).
• DO NOT store fuel or other combustible materials within marked installation clearances.
• Inspect and clean flues and chimney regularly.
• DO NOT operate your furnace with the fuel or ash doors open.
WARNING: NEVER fuel your furnace with wet, unseasoned wood or wood that has been exposed to a recent rainfall. Burning wood with
high moisture content will cause a rapid accumulation of hazardous creosote, which has been proven to be the most common cause of