Using The Switch Panel Interfaces
Frame mounted switch panel interface
Power SW Up/Down. This enables the ultrasonics. Toggle the switch up for on, toggle the switch down
for off.
Continuous Work/Test Ultrasonics Down/Middle/Continuous Work. This switch determines how the
ultrasonics works with the armature feed. Select up for continuous operation. Select the middle position
for foot pedal operation. Select the momentary down position to enable the ultrasonics for testing.
NOTE: When you select Auto on the table top switch interface Auto/Hand switch, you must select
Continuous Work. When you select Hand on the table top switch interface Auto/Hand you must select the
middle positon of this switch.
Overload Illuminated/Not. When the ultrasonics is overloaded the Overload light is illuminated.
Power Ind. Illuminated/Not. When the power switch is Up, the Power Ind. Light is illuminated.
Amp Meter. This meter indicates the loading factor of the ultrasonics.