background image

Step 3

•Feed the Sensor Wire (31) through the Upper Poster (34) and

attach the Upper Poster (34) to the Poster (30). (See Figure F.)

•Loosen Connect Console (32) from the Connect Cover (33) and

attach the Connect Console (32) to Poster (30) and the Upper
Poster (34) with Bolt (45). (See Figure G.) 

•Tighten the Connect Cover (33) to the Connect Console (32).

(See Figure H.)

Figure F.

Figure G.

Figure H.

Assembly Guide

Содержание SR410

Страница 1: ...Read and save these instructions Stair Climber with Heart Rate Monitor SR410 Instructions ...

Страница 2: ...ducts For more than 25 years The Sharper Image has shared the fun of discovering innovative products that make life easier and more enjoy able We ve been in business a long time because we are an exciting place to shop and just as importantly we strive to deliver great customer service that exceeds your expectations Enjoy your purchase Respectfully Richard Thalheimer Founder Chairman and Chief Exe...

Страница 3: ... The Stair Climber should not be used by people in poor health or those suffering from injuries The hydraulic cylinders are designed to be used continuously for 15 minutes After 15 minutes the cylinders must cool off for 15 minutes before the unit is used again The hydraulic cylinders can overheat after using the unit for a long period of time Do not touch the cylinder shafts until they have compl...

Страница 4: ...faint lightheaded or dizzy stop exercis ing immediately You should also stop exercising if you experi ence any pain or pressure Please consult your physician before beginning your program Inspect the Stair Climber prior to exercising to ensure that all nuts and bolts are fully tightened Use the Stair Climber on a flat level surface Exercise equipment has moving parts Please keep children and pets ...

Страница 5: ...ping on and off the Stair Climber Wear proper clothing and footwear during exercise Choose loose fitting workout gear that allows free movement such as jogging suits shorts etc Avoid serious injury Never place any part of your body between or near any moving parts Do not operate this or any other exercise equipment if it is damaged Safety Instructions ...

Страница 6: ...0 mm 1 11 Bushing 2 12 Cap 2 13 Plastic Bushing 4 Ø25 x Ø38 mm 14 Plastic Washer 2 No Description Qty 15 Washer Ø38 mm 2 16 Plastic Cover 2 17 Rubber Bumper 2 18 Bolt Ø8 x 40 mm 2 19 Lock Bolt 2 Ø8 x 20 mm 20 Bolt 19 x 37 mm 4 21 C Ring 4 22 Bolt Ø8 x 19 mm 1 23 Washer 1 Ø46 x Ø70 mm 24 Washer Ø38 mm 2 25 Hex Nut M8 2 26 Rear Base 1 27 Base Console 1 28 Contact Wire 1 Parts List ...

Страница 7: ...pper Poster 1 35 Monitor Support 1 36 Top Cover Ø50 mm 1 37 Lock Pin 1 includes 37A 37B 38 Bolt Ø8 x 55 mm 2 39 Bolt Ø5 x 15 mm 4 40 Bolt Ø8 x 25 mm 2 41 Nut M8 2 No Description Qty 42 Spring Washer 2 Ø8 mm 43 Lock Washer 2 Ø8 x 22 mm 44 Washer 2 Ø8 x 22 mm 45 Bolt 3 Ø8 x 22 mm 46 Washer 2 Ø8 x 19 mm Parts List ...

Страница 8: ...y 2 43 Lock Washer Ø8mm x Ø22mm Qty 2 37 Lock Pin 6mm x 92mm Qty 1 37A Washer Ø8mm x Ø18mm Qty 1 38 Bolt Ø8mm x 55mm Qty 2 Wrench Qty 1 Allen Wrench Qty 1 40 Bolt Ø8mm x 25mm Qty 2 44 Washer Ø8 Ø8mm x 22mm Qty 2 45 Bolt Ø8mm x 12mm Qty 3 46 Washer Ø8mm x Ø19mm Qty 2 37B Nut Ø4mm x Ø18mm Qty 1 ...

Страница 9: ...Illustration of Selected Parts ...

Страница 10: ... 26 to the Main Base 1 with Bolt 38 Washer 46 and Nut 41 See Figure A Remove Sleeve Cover 29 from the Main Base 1 and connect the Sensor Wire 31 to the Contact Wire 28 See Figures B and C Figure A Figure C Figure B Assembly Guide ...

Страница 11: ...sor Wire 31 through the Poster 30 See Figure D Attach the Poster 30 into the Base Console 27 with Bolt 40 and Spring Washer 42 Tighten Sleeve Cover 29 onto the Base Console 29 See Figure E Figure D Figure E Assembly Guide ...

Страница 12: ...4 to the Poster 30 See Figure F Loosen Connect Console 32 from the Connect Cover 33 and attach the Connect Console 32 to Poster 30 and the Upper Poster 34 with Bolt 45 See Figure G Tighten the Connect Cover 33 to the Connect Console 32 See Figure H Figure F Figure G Figure H Assembly Guide ...

Страница 13: ...er 34 See Figure I Insert the battery into the back of the Monitor 8 See Battery Replacement section for detailed instructions Attach the Monitor 8 to the Monitor Support 35 with Bolt 39 and place a Lock Washer 43 on both sides of the Top Cover 36 See Figure I and J Figure I Figure J Figure K Figure L Assembly Guide ...

Страница 14: ...re 31 into the hole on the back of the Monitor 8 See Figure L Battery Replacement for LCD Screen Remove the battery cover from the back of the monitor Insert 2 AA UM 3 batteries into the compartment observing proper polarities See Figure M Ensure the battery springs are in contact with the batteries Replace the battery cover Figure M Assembly Guide ...

Страница 15: ...ent To reset the values to zero remove all the batteries When you are finished exercising you do not need to press any buttons to turn off the monitor It will shut off automatically after 4 minutes The monitor will beep to remind you when a preset value has been achieved To reset all preset data except Total Count function press and hold the MODE button for 4 seconds Battery Replacement for LCD Sc...

Страница 16: ...h preset value UP Press to increase time count and calorie values before exercising Note UP button only works when the monitor is in the Stop mode DOWN Press to decrease time count and calorie values before exercising Note DOWN button only works when the monitor is in the Stop mode Functions ...

Страница 17: ...irst and the monitor counts down from that value when you begin exercise and stops when zero has been reached TOTAL COUNT Accumulates totals or repetitions during different workout sessions This data can be reset to zero only when the batteries are removed and replaced CALORIES The monitor accumulates estimated calories burned during your workout from zero up to 9 999 For countdown set your preset...

Страница 18: ...onitor displays your current heart rate For an accurate stable readout hold both hands on the grips Specifications Scan Every six seconds Time 00 00 99 59 Count 0 9 999 Calorie 0 9 999 K Cal Total Count 0 9 999 Pulse 30 240 Beats Per Minute bpm Battery Two AA or UM 3 Functions ...

Страница 19: ...ther replace this product with one of similar features and price or refund the full purchase price of the product whichever you prefer How to Obtain Service Return the product and receipt along with a brief explanation of the problem to T S I Returns Department 2901 A West 60th Street Little Rock AR 72209 If you have questions please feel free to contact our customer service representatives at 1 8...

Отзывы: