Note:
1. The alarm will automatically turn on when you set the
alarm time with the icon “
” or “
” displayed.
2. The dual-alarm (ALM1&ALM2) design of this unit will provide
you with more convenience, and you can set two-alarm time
if needed.
USING ALARM & SNOOZE FUNCTIONS
1.
Set the alarm time as described in the previous section.
2.
In normal mode(Date mode), press “ALARM SET ”
key once to turn on ALM1, press it second time to turn
on ALM2, press it third time to turn on both ALM1 and
ALM2, with the bell icons display on the LCD. Press it
again to turn off both ALM1 and ALM2, with the icons
disappearing.
3.
In ALM1/ALM2 mode, press “ALARM SET” key to turn
on/off ALM1/ALM2.
Note:
1. If no key is pressed during the alarm period, the alarm will
turn off automatically. You can also press “SNOOZE/LIGHT”
key to stop the current alarm and enter snooze with the bell
icon keep flashing.
2. Once the snooze function is turned on, the 4-step
crescendo alarm will sound in 5-minute interval. The alarm
duration is 120 seconds.
3. The snooze function won’t stop unless you press “ALARM
SET” key to turn off the alarm and snooze.
ABOUT THE WEATHER INDICATOR
The built-in barometer can notice atmosphere pressure
changes. Based on the data collected, it can predict the
weather conditions in the forthcoming 12-24 hours.
Note:
1. The accuracy of a general pressure-based weather
forecast is about 70% to 75%.
2. The weather forecast is meant for the forthcoming 12-24
hours. It may not necessarily reflect the current situation.
VIEW THE CHANNEL
1.
The defaulted displayed channel is channel 1. In
normal mode, press “CH/+” key to check the outdoor
temperature from channel 1 to channel 3.
2.
Press and hold “CH/+” key for 2 seconds to turn to
channel auto-change mode that the channels change
automatically.
3.
Press “CH/+” key again to return to normal mode.
Note:
In channel auto-change mode, channels change automatically
in every 4 seconds.
READING INDOOR&OUTDOOR TEMPERATURE
RECORDS
2.
Press “CH/+” key to change the channels among 3
channels and check their temperature.
CHECKING AND DELETING MAX./MIN. TEMPERATURE
AND THE DATE&TIME RECORDS
1.
Press “MEM/-” key to check the maximum / minimum
outdoor/indoor temperature and the date&time records
for 5 seconds.
2.
Press and hold the “MEM/-” key for 3 seconds to
delete the maximum and minimum temperature records.
Note:
Once you reset or re-install batteries for the main unit, all
the value will be defaulted.
ICE ALERT
1.
When the outdoor temperature within the range of
-2°C~3°C (28°F~37°F), the Ice Alert icon “ ” will
display on LCD & flashing continuously.
2.
Ice Alert icon “ ” will disappear when outdoor
temperature out of above temperature range.
USING THE PROJECTOR AND BACKLIGHT
A. When the clock is powered by battery:
1.
When the clock is powered by battery, press “SNOOZE/
LIGHT” key to turn on the projector and backlight for
5 seconds.
2.
Or press and hold “SNOOZE/LIGHT” key for 4 seconds
to turn on the projection for 30 minutes. During the
projection, press the “SNOOZE/LIGHT” key again to
turn off the projection.
B. When the clock is powered by DC adaptor:
3.
Slide the “PROJECTION ON/OFF” switch to ON
position, the projection will be on all the time, or slide
it to OFF position to return to normal mode(Like section
A).
4.
Slide the “LIGHT ON/OFF” switch to ON position, the
backlight will be on all the time, or slide it to OFF
position to return to normal mode(Like section A).
Note:
1. During the projection, press the “ ” key will reverse the
projected data.
2. The rotate angle of the projector is ±90º.
3. Adjust the quality of the projected data by adjusting the
FOCUS knob.
BATTERY REPLACEMENT
When the LCD becomes dim, replace with 2 AA size batteries
at once; while if the low battery indicator “ ” displays in
the outdoor window, it indicates that the battery power of
the transmitter is not enough, and you should replace with 2
AA size batteries at once.
Note:
Attention! Battery shall not be exposed to excessive heat
such as sunshine, fire or the like. Please dispose of used
unit or batteries in an ecologically safe manner.
SUGGESTION
1.
Everyday the unit will automatically search for the
time signal at 2:00, 8:00, 14:00 and 20:00.
2.
Always place the unit away from interfering sources
such as TV set, computer, etc.
3.
Avoid placing the unit on or next to metal plate.
4.
Closed area such as airport, basement, tower block or
factory is not recommended.
5.
Do not start reception on a moving article such as
vehicle or train.
SPECIFICATION
MAIN UNIT
Temperature measurement
range:
Recommended operating
range:
Resolution:
Radio Controlled signal:
REMOTE SENSOR
Temperature measurement
range:
Recommended operating
range:
Resolution:
RF transmission frequency:
RF transmission range:
No. of remote sensor:
Temperature sensing cycle:
POWER
Main unit:
Remote sensor:
DIMENSION
Main unit:
Remote sensor:
Normal mode(Alarm 1)
Hour setting
Minute setting
Normal mode(Alarm 2)
Hour setting
Minute setting
Sunny
Slight cloudy
Cloudy
Rainy
Channel 1
Channel 2
Channel3
Ice alert icon
-40.0~70.0°C
(-40.0~158.0°F)
0~45.0°C
(32.0~113.0°F)
0.1°C/°F
-40.0~70.0°C
(-40.0~158.0°F)
-20.0~55.0°C
(-4.0~131.0°F)
0.1°C/°F
433 MHz
Up to 3 units
Around 60~64seconds
3V, use 2×AA 1.5V battery
3V, use 2×AA 1.5V battery
130(W)×90(H)×47(D)mm
65(W)×100(H)×35(D)mm
Note:
1. Once the channel is assigned to one transmitter, you can
only change it by removing the batteries or resetting the unit.
2. If no signals are received or the transmission is interfered,
“—-” will appear on the LCD.
3. Relocate the clock or the transmitter in other positions
and make sure the transmission is within the effective
range of 50 meters approx.
4. After several trials in vain, please reset the clock thoroughly.
Try out where your multifunctional alarm clock receives the
signals best.
1.
Slide “°C/°F” switch to change the temperature unit to
Celsius or Fahrenheit. (For WWVB version,the
defaulted temperature unit is °F)
WWVB
Maximum 50 meters
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2)
this device must accept any interference received,
including interference that may cause undesired operation.
Warning:
Changes or modifications to this unit not expressly
approved by the party responsible for compliance could
void the user's authority to operate the equipment.
Note:
This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to Part 15 of
the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a
residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference
by one or more of the following measures:
receiver.
different from that to which the receiver is needed.
technician for help.
Responsible Party in USA
Legal Company Name: Camelot SI.
Address: 27725 Stansbury Blvd., Ste. 175, Farmington Hills,
MI 48334 USA
Phone, Fax: 1-877-714-7444