Sharpe D-5-55 Скачать руководство пользователя страница 6

Troubleshooting 

6

Troubleshooting

Technical Data

Maximum Air Inlet Pressure: 50 psi (345 kPa, 3.4 bar)

Wetted Parts: stainless steel, aluminum, brass, 
LD polyethylene

Air Consumption: 4.1 scfm at 50 psi (345 kPa, 3.4 bar)

Spray Gun

1/4 npsm (R1/4-19) air inlet

1/4 npsm fluid inlet

Weight - 8 oz. (227 grams)

Pressure cup: 6 oz. (177 cc)

Problem

Cause

Solution

Normal pattern

No action necessary

Dirty or damaged air cap or fluid
nozzle.

Rotate air cap 180°.

If pattern follows air cap, problem is in air cap. Clean 
and inspect. If pattern is not corrected, replace air cap.

If pattern does not follow the air cap, the problem is 
with the fluid nozzle. Clean and inspect the nozzle. If 
the pattern is not corrected, replace nozzle.

Pressure too high for viscosity of mate-
rial being sprayed.

a. Reduce air pressure.

b. Increase material viscosity

c. Correct pattern by narrowing fan size with spray 

width adjustment knob.

Dirty or distorted air horn holes.

Rotate air cap 180°.

If pattern follows air cap, problem is in air cap. Clean 
and inspect. If pattern is not corrected, replace air cap.

Will not spray.

a. Cup is not tight

a. Tighten cup lid.

b. Cup empty.

b. Fill cup.

c. Air cap not seated.

c. Turn spray width adjustment knob fully counter-

clockwise. Tighten air cap.

a. Air pressure too low.

a. Increase air pressure.

b. Gun held too close to surface.

b. Hold gun about 6-8 inches (150-200 mm) from sur-

face.

Right

Wrong

Heavy top or 

bottom pattern

Wrong

Split pattern

Wrong

Wrong

Heavy pattern or 

orange peel

Содержание D-5-55

Страница 1: ...ng of automotive colors and clears Ideal for touch up and detail work Maximum Air Inlet Pressure 50 psi 345 kPa 3 4 bar Part No 7030 Spray Gun and 7510 Cup Important Safety Instructions Read all warnings and instructions in this manual Save these instructions 309991E ENG II 2 G ...

Страница 2: ...l equipment manuals Use fluids and solvents that are compatible with equipment wetted parts See Technical Data in all equipment manuals Read fluid and solvent manufacturer s warnings For complete information about your material request MSDS from distributor or retailer Do not leave the work area while equipment is energized or under pressure Turn off all equipment and follow the Pressure Relief Pr...

Страница 3: ...this is first time using the equipment flush the spray gun TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin inhaled or swallowed Read MSDSs to know the specific hazards of the fluids you are using Store hazardous fluid in approved containers and dispose of it according to applicable guidelines PERSONAL PROTECTIVE EQUIPMENT You m...

Страница 4: ...l Do not fill past cup shoulder A See FIG 1 2 Screw cup 101 onto lid securely 3 Slowly adjust gun air pressure while fully triggering the gun until you have the desired atomization 4 Adjust the pattern size and shape with the spray width adjustment knob 10 See FIG 2 Turn knob clockwise to reduce pattern size and counterclock wise to increase it NOTE See Troubleshooting guide if you experience an i...

Страница 5: ...cribed in Spray Gun Maintenance Cleaning Nozzle and Air Cap To clean the air cap and nozzle remove and soak them in a compatible cleaning solution Clean them and front of gun with a soft bristle brush dipped into compatible solvent Do not use a wire brush or metal tools To clean out air cap holes use a soft implement such as a toothpick Spray Gun Maintenance Frequently lubricate the gun moving par...

Страница 6: ...an and inspect the nozzle If the pattern is not corrected replace nozzle Pressure too high for viscosity of mate rial being sprayed a Reduce air pressure b Increase material viscosity c Correct pattern by narrowing fan size with spray width adjustment knob Dirty or distorted air horn holes Rotate air cap 180 If pattern follows air cap problem is in air cap Clean and inspect If pattern is not corre...

Страница 7: ...king Nut 1 4 26022 Needle Packing 1 5 29047 Plunger 1 6 29036 Needle Spring 1 7 29046 Fluid Control Knob 1 8 29056 Trigger Screw 1 9 29055 Trigger 1 10 29030 Width Control Assembly Includes items 10a 10d 1 10a 118749 Knob 1 10b 118741 Packing Nut 1 10c 29028 Packing 1 10d 29029 Retaining Ring 1 11 29041 Fluid Needle 1 12 29021 Fluid Nozzle 0 55 1 13 29006 Air Cap 1 Parts included in Repair Kit 290...

Страница 8: ...der of the original warranty period Sharpe or its authorized service representatives must perform all warranty repairs Any repair to the product by unau thorized service representatives voids this warranty The rights under this warranty are limited to the original user and may not be transferred to subsequent owners This warranty is in lieu of all other warranties expressed or implied including wa...