Replacing the
With the top cabinet removed
(1) Remove three screws off the output shield.
(2) Disconnect the LCD flat cable from the output PWB connector.
(3) Remove the lock screws
and
Detach the R/B adjusting plate or the
LCD panel.
(4) Separate the LCD panel from the adjusting plate.
(5) Mount a new LCD panel in the reverse order of the above steps
(3) and (4).
Readjust the convergence and focus. Note that the LCD panel needs no convergence adjustment and has
a small adjustment range in the direction.
TOP VIEW
FRONT
7
Lock screws
adjusting plate
G-LCD
SIDE VIEW
3
Lock screws
adjusting plate
panel
mounting screws
VIEW
mounting screws