WQ-790W
FITTING OF DIAL POINTER
FOR A COMPLETE DESCRIPTION OF THE OPERATION OF THIS UNIT, PLEASE REFER
TO THE OPERATION MANUAL.
– 2 –
9FF24801830210
AC POWER SUPPLY CORD AND PLUG
9FF24801600292
9FF26802125210
9FF26802125120
VOLTAGE SELECTION
Before operating the unit on mains, check the preset voltage. If the voltage is different from your local voltage, adjust the voltage
as follows: Slide the AC power supply socket to the visible indication of the side of your local voltage.
1. Remove the main PWB. Attach the dial pointer as shown
arrow on the front cabinet, putting it into the section
indicated by arrow .
2. Install the main PWB in the front cabinet and secure it with
the four screws.
3. Turn the tuning control knob in the direction indicated by .
Set the dial pointer to point "0", and then make the rest of
the adjustments.
A
B
C
Figure 2
Front Cabinet
Dial Pointer (234)
Screw (608)
ø3x10mm
Main PWB
Tuning Control
Knod (233)
Dial Drum (231)
B
A
C
Dial Pointer
(234)
"0" Point