28
R-55TS
Removal
1. Disconnect the power supply cord and then remove the
outer case.
2. Open the oven door and block it open.
3. Discharge the high voltage capacitor.
4. Disconnect all wire leads from the magnetron and the
oven lamp.
5. Remove the two (2) screws holding the chassis support
to the oven cavity front flange and the bottom plate
assembly. And remove the chassis support.
6. Release the snap band of the main wire harness from
the air duct.
7. Remove the two (2) screws holding the C/T fuse to the
air duct.
8. Remove the one (1) screw holding the thermistor angle
to the magnetron.
9. Carefully remove the three (3) screws holding the
magnetron to the waveguide flange.
10.Remove the magnetron with care so that its antenna is
not hit by any metal object.
11.Remove the two (2) screws holding the air duct to the
magnetron and remove it.
12.Remove the two (2) screws holding the reflector to the
magnetron and remove it.
13.Now, the magnetron is free.
Reinstallation
1. Reinstall the reflector to the magnetron with the two (2)
screws.
MAGNETRON REMOVAL
HIGH VOLTAGE RECTIFIER AND HIGH VOLTAGE CAPACITOR REMOVAL
1. Disconnect the power supply cord and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the high voltage wire of the power transformer
from the high voltage capacitor.
5. Disconnect the high voltage wire of high voltage rectifier
assembly from the magnetron.
6. Disconnect the filament lead (short one) of the power
transformer from the high voltage capacitor.
7. Remove the two (2) screws holding capacitor holder to
bottom plate.
8. Remove one (1) screw holding high voltage rectifier
assembly to capacitor holder.
9. Disconnect rectifier terminal from capacitor.
High voltage rectifier assembly is now free.
10.Remove capacitor holder. Capacitor is now free.
CAUTION: WHEN REPLACING HIGH VOLTAGE RECTI-
FIER AND HIGH VOLTAGE CAPACITOR,
GROUND SIDE TERMINAL OF THE HIGH
VOLTAGE RECTIFIER MUST BE SECURED
FIRMLY WITH A GROUNDING SCREW.
CAUTION: 1. DISCONNECT OVEN FROM POWER SUP
PLY BEFORE REMOVING OUTER CASE.
2. DISCHARGE THE HIGH VOLTAGE CA-
PACITOR BEFORE TOUCHING ANY OVEN
COMPONENTS OR WIRING.
NOTE: When replacing the outer case, the 2 special
Torx screws must be reinstalled in the same
locations.
1. Disconnect the power supply cord and then remove
outer case.
2. Open the oven door and block it open.
3. Discharge high voltage capacitor.
4. Remove two (2) screws holding the capacitor band with
the high voltage capacitor to the bottom plate assembly.
5. Disconnect wire leads (primary) from power transformer
and the filament leads and high voltage wire from the
magnetron and capacitor terminals.
6. Remove four (4) screws holding transformer to bottom
plate (from bottom side ).
7. Remove transformer from bottom plate.
POWER TRANSFORMER REMOVAL
Reinstallation
1. Rest transformer on the bottom plate with its primary
terminals toward the oven face plate.
2. Secure transformer with four (4) screws (from bottom side)
to bottom plate.
3. Reconnect wire leads (primary) to power transformer
and filament leads and high voltage wire of transformer
to magnetron and high voltage capacitor. Refer to
"PICTORIAL DIAGRAM".
4. Reinstall the capacitor band with the high voltage
capacitor to the bottom plate assembly with two (2)
screws.
5. Reinstall outer case and check that oven is operating
properly.
Special screw
Screw Driver
(Type: TORX T20 H or
GTXH20-100)