![Sharp VL-PD3AE Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/sharp/vl-pd3ae/vl-pd3ae_service-manual_366483037.webp)
37
VL-PD3AS/AH/AE
9-2-4. Adjustment procedures
Item
Adjustment method
(1) Auto-focus adjustment
Set the unit to the auto-focus function adjustment mode and write data to the address "09FD" one after another. This executed
the adjustments automatically. The items to be adjusted are as listed below. Every time an adjustment is made properly, the data
"FF" is written to the address. After each adjustment, make sure that the adjustment has been made properly, and then go on to
the next adjustment item.
Address
Data
Adjustment item
09FD
000C
MR censor adjustment
0012
WIDE end adjustment
0008
TELE end focus
∞
position adjustment
0006
WIDE end focus
∞
position adjustment
Note 1: To adjustment of
∞
position is executed by actually picking up the image of subject. For this adjustment use the subject with
clear profile.
Especially, if the adjustment of TELE end focus
∞
position is made without picking up the image of remote subject,
adjustment failure may occur.
Adjustment of WIDE end focus
∞
position: 3 m or more
Adjustment of TELE end focus
∞
position: 50 m or more
Note 2: In case of
∞
position adjustment the field depth is important to ensure the adjustment accuracy. If the field depth is high,
the focus becomes too stable , which may cause incorrect adjustment of
∞
position. Therefore the adjustment must be made
with low field depth (with iris opened).
The iris can be opened with the high-speed shutter.
1. It returns to the normal operation mode.
2. In the normal operation mode, set the high-speed shutter mode until the iris is opened. (Refer to the operation manual.)
3. Display “CAM ADJ” with the remote control for service.
4. It shifts to the auto-focus adjustment mode.
5. Perform the
∞
position adjustment.
6. After completing the
∞
position adjustment, return the high-speed shutter mode to the normal mode.
(2) Iris basic adjustment
This is for adjusting the operating point of the hole element installed in the iris meter of the lens.
The adjustments are executed automatically by writing the data to the address "09FD" one after another in the auto-focus
adjustment mode.The items to be adjusted are as listed below. Every time an adjustment is made properly, the data "00FF" is
written to the address.
Address
Data
Adjustment item
09FD
0009
Hall offset adjustment
000A
Iris offset adjustment
000B
Iris close adjustment
*
After completion of 1. Auto-focus adjustment, 2. Iris basic adjustment once restore the regular operation mode. Data "090F" is
written in the address "0003".
(3) Black balance adjustment/A/F noise adjustment
1) In the camera signal system adjustment mode (write the data " 00" to the address "0000"), set the unit to the
adjustment mode.
2) Prior to the adjustment, initialize the data for the addresses "0200", "0202", "0204", "0206", "0208", "020A".
Write " FF" to all of these address.
3) Write the data " 01" to the address "0001" This starts the adjustment automatically.
When the adjustment is completed properly, the data "00FF" is written automatically.
F
F
Содержание VL-PD3AE
Страница 3: ...3 VL PD3AS AH AE 2 PART NAMES For details on the use of each control ...
Страница 81: ...109 VL PD3AS AH AE MAIN1 PWB Wiring Side SIDE A A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 ...
Страница 83: ...111 VL PD3AS AH AE MAIN1 PWB Wiring Side SIDE B A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 ...
Страница 85: ...113 VL PD3AS AH AE MAIN2 PWB Wiring Side SIDE A A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 ...
Страница 87: ...115 VL PD3AS AH AE MAIN2 PWB Wiring Side SIDE B A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 ...
Страница 94: ...VL PD3AS AH AE 122 M E M O ...