39
VC-TA350/TA351/351W
VC-TA352W/TA355/TA356
FLOW CHART NO.10 INFRARED R/C TROUBLESHOOTING
No operation is possible from the infrared remote control.
Does the infrared remote control
function?
Replace infrared remote control as
required.
Is the supply voltage of 5V fed to C804
of (+) side?
Check AT 5V and GND lines.
Is "L" pulse sent out from pin(1) of the
receiver when the infrared remote
control is activated?
Replace receiver.
Check between at pin(1) of receiver and
all the way up through to pin (5) of IC701.
Replace IC701.
YES
NO
YES
NO
NO
NO
YES
Is the cassette housing distorted?
Fix or replace the cassette housing.
NO
YES
YES
YES
YES
NO
YES
NO
NO
YES
NO
YES
FLOW CHART NO.11 CASSETTE CONTROL TROUBLESHOOTING(1)
A cassette tape is not take in.
NO
NO
Check start sensor cover.
Check line between start sensor and
pin (79) of IC701
Check line between pin (91) of IC701
and pin(11) of IC706.
Is the supply voltage of 12V fed to pin
(9) of IC706?
Check M 12V lines.
Check IC706.
Check line between IC706 and loading
motor.
Replace loading motor.
Is the specified voltage applied at the
loading motor terminal when the
cassette tape is inserted?
Does pin(12) of IC706 change to about
10V when the cassette tape in inserted?
Does pin(13) of IC706 go to a "H" level
when the cassette tape is inserted?
Does pin(79) of IC701 change from"H"
to "L" level when the cassette tape is
inserted?
Does the start sensor cover go to open
when the cassette tape is inserted?
NO
NO
NO
FLOW CHART NO.12 CASSETTE CONTROL TROUBLESHOOTING(2)
A cassette tape is taken in, but ejected at once.
Does the start sensor pulse at pin (79)
of IC701 change from "L" to "H" level
when the cassette tape is loaded?
Check line between start sensor and pin
(79) of IC701.
Does the end sensor pulse at pin (85)
of IC701 change from "L" to "H" level
when the cassette tape is loaded?
Check line between end sensor and pin
(85) of IC701.
Does the master cam mode shifter
operate normally when the cassette
tape is loaded?
Check line between cam switch and
IC701.
Replace IC701.
YES
YES
YES
FLOW CHART NO.13 LOADING MOTOR AND EJECT TROUBLESHOOTING
The cassette tape fails to come out.
Does the capstan motor start when the
EJECT button is pressed?
See FLOW CHART NO.14 CAPSTAN
MOTOR TROUBLESHOOTING
Does the take-up reel disk turn when the
capstan motor is running?
Check line between take-up reel
sensor and pin(2) of IC701.
Is a "H" level applied at pin(12) of IC706
when a reel pulse has been inputted?
Check line between pin(90) of IC701
and pin(12) of IC706.
Is the supply voltage of 12V fed to
pin(9) of IC706?
Is the voltage about 10V sent out from
pin(15) of IC706?
Check IC706.
Is the specified voltage applied at the
loading motor terminal?
Check line between IC706 and
loading motor.
Does the loading motor run?
Replace loading motor.
Replace cassette cam, gear, etc.
YES
YES
YES
Check M 12V lines.
NO
YES
NO
YES
YES
YES
NO
NO
NO
NO
NO