SW-H2 No. 1, No. 2 Number of Busy tone pulses
Used to set detection of Busy tone intermittent sounds.
SW-H2 No. 3 Fax switching when A.M. full or PC failure
If the answering machine’s memory (tape) is full and there is no
response, the machine automatically switches to Fax reception.
SW-H2 No. 4 ~ No. 8 Reserved
Set to "0".
SW-I1 No. 1 ~ No. 7 Reserved
Set to "0".
SW-I1 No. 8 CPC signal detection
Used to turn ON/OFF the CPC (Calling Party Control) signal detection
in the TEL/FAX automatic switching mode.
SW-I2 No. 1 ~ No. 5 Reserved
Set to "0".
SW-I2 No. 6, No. 7 CPC detection time
Used to set the CPC (Calling Party Control) signal detect time.
SW-I2 No. 8 Reserved
Set to "0".
SW-I3 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I4 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I5 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I6 No. 1 ~ No. 8 Reserved
Set to "0".
SW-I7 No. 1 ~ No. 8 Reserved
Set to "0".
SW-J1 No. 1, No. 2 Reserved
Set to "0".
SW-J1 No. 3 Sender’s phone number registration
Used to make a choice of whether the registered sender’s phone
number can be changed or not. If the switch is set to "1", new regis-
tration of the sender’s phone number is disabled to prevent accidental
wrong input.
SW-J1 No. 4 Country setting
Used to select UK or IRELAND use.
SW-J1 No. 5 Reserved
Set to "0".
SW-J1 No. 6 Summer time setting
Used to set YES/NO of automatic clock adjustment for European
Summer time.
SW-J1 No. 7, No. 8 Ringer volume
Used to adjust ringing volume.
SW-J2 No. 1, No. 2 Reserved
Set to "0".
SW-J2 No. 3 Polling function
If this switch is set to 1, the last of Rapid key works as polling key.
SW-J2 No. 4, No. 5 Reserved
Set to "0".
SW-J2 No. 6 ~ No. 8 Speaker Volume (For H, A)
Used to adjust sound volume from a speaker.
SW-J3 No. 1, No. 2 Reserved
Set to "0".
SW-J3 No. 3, No. 4 Transaction report (Communication result
printout)
It is possible to obtain transaction results after each communication.
Normally, the switch is set (No. 1: 0, No. 2: 0) so that the transaction
report is produced only when a communication error is encountered.
If No. 1 was set to "1" and No. 2 to "0", the transaction report will be
produced every time a communication is done, even if the communi-
cation was successful.
Setting No. 1 to 1 and No. 2 to 1 will disable this function. No transac-
tion report printed.
SW-J3 No. 5 ~ No. 8 Reserved
Set to "0".
SW-K1 No. 1 Entering DIAG mode by pressing SPEED key
A bit which is used in the production process only. When the SPEED
key pressed, the switch is changed from the stand-by state to the
DIAG mode.
SW-K1 No. 2 ~ No. 8 Reserved
Set to "0".
SW-L1 No. 1 ~ No. 8 Reserved
Set to "0".
SW-L2 No. 1 ~ No. 8 Reserved
Set to "0".
Caution
When the value which the user is not allowed to set using the soft SW is set, output to the indication or list is not performed. However, the actual
operation is performed at the set value.
(Example) Number of rings for auto receive SWD1 No. 1-No. 4
0100 1111 Display" ENTER (1-5)(4) List 4RINGS
(4times) (15times)
Set value Value when shipping Value when shipping
The
operation
is
performed
15
times.
UX-177H
2 – 14
Содержание UX-177
Страница 58: ...6 6 Control PWB parts layout Top side UX 177H ...
Страница 59: ...6 7 Control PWB parts layout Bottom side UX 177H ...
Страница 63: ...6 11 TEL LIU PWB parts layout Top side UX 177H ...
Страница 64: ...6 12 TEL LIU PWB parts layout Bottom side UX 177H ...
Страница 66: ...6 14 Power supply PWB parts layout UX 177H ...
Страница 69: ...Operation panel PWB parts layout 6 17 UX 177H ...
Страница 78: ...M E M O UX 177H 8 7 ...
Страница 99: ...M E M O UX 177H ...