background image

18

3

4. TIME key:
    - In normal time mode, press it to enter alarm1 and

alarm2 time mode.

    - Press and hold it for 2 seconds to enter the normal

time setting mode.

    - In normal time setting mode, press it to step the setting

items.

5. UP key:
    - In normal time mode, press it to switch between M-D

(Month-Date) and D-M (Date-Month) formats.

    - In alarm time mode, press it to select the proper time

zone.

    - In time setting mode, press it to increase the setting

values.

    - Press and hold it for 3 seconds to receive the RC signal

for reception testing.

6. DOWN key:
    - Press it to switch 12/24-hour format.
    - In time setting mode, press it to decrease the setting

values.

7. MAX/MIN key:
    - Press it to show the maximum and minimum

temperature records.

    - Press and hold it for 3 seconds to delete the maximum

and minimum temperature records.

TWO  YEAR  LIMITED  WARRANTY

M.Z. Berger & Company warrants the original consumer
purchaser of this product that it shall be free of defects in
materials and workmanship for two years from the purchase
date of this product. Defects caused by tampering, improper
use, unauthorized modifications or repairs, immersion in
water or abuse are not covered by this warranty. If a defect
covered by this warranty occurs during the warranty period,
wrap your clock carefully and send it to the following address:

M.Z. Berger Service Center

29-76 Northern Boulevard

Long Island City, NY

11101-2224

You must include a proof of purchase, either the original
receipt of a photocopy and a check or money order for
US$5.95 to cover the cost of handling. Also include your
return address inside the package. M.Z. Berger & Company
will repair or replace the clock and return it to you. M.Z. Berger
& Company will not be liable for any loss or damage,
including incidental or consequential damages of any kind;
from any breach of warranty either expressed or implied
relating to the product. Since some states do not allow the
exclusion or limitation of incidental or consequential
damages, this limitation may not apply to you. This warranty

Содержание SPC900

Страница 1: ...P178318GB010 C8318A WWVB PD09025M Size 105 x 130 mm RADIO CONTROLLED WIRELESS THERMO CLOCK USER S INSTRUCTIONS ...

Страница 2: ...time signal transmitted from USA WWVB reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate ratio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Страница 3: ...ate to state Printed in China SPC900 SHARP registered in the U S Patent and Trademark Office This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Changes or modifications to this...

Страница 4: ...t it shall be free of defects in materials and workmanship for two years from the purchase date of this product Defects caused by tampering improper use unauthorized modifications or repairs immersion in water or abuse are not covered by this warranty If a defect covered by this warranty occurs during the warranty period wrap your clock carefully and send it to the following address M Z Berger Ser...

Страница 5: ... CHANNEL key Press it to switch between channel 1 and 2 Press and hold it for 2 seconds to show the channels automatically and press it once again to exit the automatic display mode 11 C F key Press it to switch between Celsius and Fahrenheit 12 RESET key Press it to reset all values to default values In case of malfunction the unit may be required to reset RF transmission frequency No of remote u...

Страница 6: ... Note Channel 3 is not effective for this model 3 RESET key Press it to restart the transmitter and return all values to default values 4 BATTERY COMPARTMENT Accommodates 2 AA size batteries 3 2 4 6 1 6 5 7 SPECIFICATIONS MAIN UNIT Recommended operating range Resolution REMOTE SENSOR Recommended operating range Resolution 0 C to 45 C 32 F to 113 F 0 1 C above 9 9 C 1 C below 10 C 0 1 F 9 9 F 99 9 ...

Страница 7: ...ANNEL key to set the desired channel NOTE 1 The building material and position of receiver and transmitter affect the effective range So try various locations to obtain the best result 2 Place the units away from metal objects and electrical appliances to minimize the interference Position the receiver within the effective transmission range 330 feet 100 meters in usual circumstances For the trans...

Страница 8: ...irst time after inserting the batteries or pressing RESET key the clock will start to receive the signals and the reception display will flash in 8 seconds BATTERY REPLACEMENT If the low battery indicator appears beside the outdoor temperature of main unit it indicates that you should replace batteries of transmitter at once While if the low battery indicator displays beside the indoor temperature...

Страница 9: ...5 Do not start reception in moving articles such as vehicles or trains No signal quality Acceptable signal quality Excellent signal quality Weak signal quality HOW TO READ TEMPERATURE RECORDS Change the temperature unit to C for Celsius or F for Fahrenheit by pressing C F key NOTE 1 If no signals are received or the transmission is interfered will appear on the LCD 2 Relocate the clock or transmit...

Страница 10: ...igit flashes 2 Press UP or DOWN key to change its value 3 Press TIME key once until the Month digit flashes 4 Press UP or DOWN key to change its value 2 The temperature pre alarm can sound 30 minutes earlier than the alarm only when the outdoor temperature is below 26 0 F 3 0 C 3 If no key is pressed during the alarm period the clock will enter the snooze mode automatically Besides you can also pr...

Страница 11: ...de 2 Press and hold ALM ON OFF key for 2 seconds until the alarm Hour digit flashes 3 Press UP or DOWN key to change its value 4 Press ALM ON OFF key once until the alarm Minute digit flashes 5 Press UP or DOWN key to change its value 6 Press ALM ON OFF key to save and exit the setting mode or let it exit automatically 30 seconds later without pressing any key NOTE 1 The alarm will be automaticall...

Отзывы: