Sharp SMD2499FS Скачать руководство пользователя страница 2

 2

E

F

E

H

D

G

I

A

B

C

J

CLEARANCES AND DIMENSIONS

Dimensions that are shown in Figure 1 must be used. Given

dimensions provide minimum clearance. Locate electrical outlet 

in the shaded area in the upper left-hand corner of the cutout. See 

Figure 9.

Contact surface must be solid and level. Pay special attention to

the floor on which the Convection Microwave Drawer will sit.

The floor of the opening should be constructed of plywood strong

enough to support the weight of the oven (about 100 pounds).

Check location where the Convection Microwave Drawer will be 

installed for proper electrical supply.

Your oven can be built into a cabinet or wall as a stand-alone unit.

It can also be installed under: 

Wall Ovens: Gas or Electric

SuperSteam oven: SSC2489DS

Cooktop Models: SDH3042DB, SDH3652DB, SCR3042FB, 

SCR2442FB, SCR3041GB, SCH3043FB, SCH2443FB, 

SDH3042DB or SDH3652DB.

Be sure that the clearance of the floor between the wall oven and

the Convection Microwave Drawer is a minimum of 2-inches.

The Convection Microwave Drawer interior will easily accom-

modate a 9" x 13" oblong dish or a bag of microwave popcorn.

The oven can also be mounted flush.  Please see instructions for

flush mounting.

24" CONVECTION MICROWAVE DRAWER STANDARD MOUNT AND MEASUREMENTS

B

C

G

D

A

B

C

D

E

I

F

G

H

I

J

K

L

M

A

F

E

Figure 1

Figure 2

A. Suggested electrical outlet

location*

B. 5" (127 mm)

C. 4" (101.60 mm)

D. 22 

3

/

8

" (568.32 mm) opening

E. 19  

3

/

8

" (492.12 mm)

F. Allow 

5

/

8

" (15.87 mm)

overlap

G. 23 

1

/

2

" (596.90 mm)

minimum depth

H. Allow 

1

/

8

" (3.17 mm) overlap

I. 36" (914.40 mm) countertop

height

J. Allow 

1

/

2

" (12.7 mm)

minimum space

K. Floor must support

100 lb (45.4 kg)

L. 24" (609.60 mm) cabinet

minimum

M. 19 

3

/

8

" (492.12 mm) opening

Figures 1 and 2 contain many Convection Microwave Drawer 

measurements for reference when planning the drawer’s location.

* Can also be installed using an electrical outlet in an adjacent cabinet 

within the area where the provided electrical cord can reach. Power 

cord access hole in cabinet should be a minimum 1

1

/

2

" diameter hole

and deburred of all sharp edges.

IMPORTANT

 

Always allow sufficient power cord length to the

electrical outlet to prevent tension.
Always check electrical codes for requirements.

A.

21 

7

/

8

" (555.56 mm)

B.

11

/

16

" (119.06 mm)

C.

3

/

4

" (44.45 mm)

D.

20 

7

/

8

" (5

30.23

 mm)

E.

23 

5

/

8

" (600.07 mm)

F.

19 

1

/

2

" (495.3 mm)

G. 19 

1

/

4

" (488.95 mm)

H. 1 

5

/

8

" (41.27 mm) door thickness

I. 15 

1

/

2

" (393.7 mm) auto drawer

opening

J. 4" (101.60 mm)

Содержание SMD2499FS

Страница 1: ...VER LEAVE CHILDREN ALONE OR UNATTENDED IN THE AREA WHERE A CONVECTION MI CROWAVE DRAWER IS IN USE NEVER LEAVE THE DRAWER OPEN WHEN THE OVEN IS UNATTENDED STEPPING LEANING OR SITTING ON THE DRAWER MAY RESULT IN SERIOUS INJURIES AND CAN ALSO CAUSE DAMAGE TO THE CONVECTION MICROWAVE DRAWER Do not use the Convection Microwave Drawer as a storage space This creates a potentially hazardous situation Che...

Страница 2: ... popcorn The oven can also be mounted flush Please see instructions for flush mounting 24 CONVECTION MICROWAVE DRAWER STANDARD MOUNT AND MEASUREMENTS B C G D A B C D E I F G H I J K L M A F E Figure 1 Figure 2 A Suggested electrical outlet location B 5 127 mm C 4 101 60 mm D 22 3 8 568 32 mm opening E 19 3 8 492 12 mm F Allow 5 8 15 87 mm overlap G 23 1 2 596 90 mm minimum depth H Allow 1 8 3 17 m...

Страница 3: ...nt visibility and access to controls See Figure 4 Move oven location downward for extended countertops Extended countertops Figure 4 Figure 3 A 25 635 mm B 1 2 12 7 mm minimum C 19 1 2 495 3 mm D 36 914 40 mm E Control panel shown in open position F 24 609 60 mm G 34 1 2 876 30 mm 24 CONVECTION MICROWAVE DRAWER STANDARD MOUNT AND MEASUREMENTS ...

Страница 4: ... location B 5 127 mm C 4 101 60 mm D 23 7 8 606 43 mm E 19 3 8 492 12 mm F 1 5 8 41 27 mm G 23 1 2 596 90 mm minimum depth H 23 5 8 600 07 mm I 1 5 8 41 27 mm to front of shelf J 19 3 4 501 65mm opening K Floor must support 100 lb 45 4 kg A 22 3 8 568 32 mm mounting cleat opening width B 0 flush C 1 5 8 41 27 mm front of cleat to cabinet face C Front view No oven shown B A Suggested electrical out...

Страница 5: ... wall receptacle that is properly installed and grounded in accordance with the National Electrical Code and local codes and ordinances In the event of an electrical short circuit grounding reduces risk of electric shock by providing an escape wire for the electric current Improper use of the grounding plug can result in a risk of electric shock Do not use an extension cord If the power supply cor...

Страница 6: ...cleaning instructions BEFORE YOU CALL FOR SERVICE Read the BEFORE YOU CALL and operating instruction sections in your Operation Manual It may save you time and expense The list includes common occurrences that are not the result of defective workmanship or materials in this oven Refer to the warranty in your Operation Manual for Sharp s toll free service number and address Please call or write if ...

Страница 7: ......

Страница 8: ...TINSEB580MRR0 Dec 3 2020 SHARP ELECTRONICS CORPORATION 100 Paragon Drive Montvale New Jersey 07645 USA ...

Отзывы: