EN -15-
CHAPTER -6: TROUBLESHOOTING
If your fridge is not operating;
• Is there a power failure?
• Is the plug connected to the socket correctly?
• Is the fuse of the socket to which the plug is connected or the main fuse blown?
• Is there any failure at the socket? To check this, plug your refrigerator into a known working socket.
If your fridge is not cooling enough;
• Is the temperature adjustment right?
ERROR TYPE
MEANING
WHY
WHAT TO DO
E08
Low Voltage Warning
Power supply to the device
has dropped to below
170W.
-
This is not a device failure, this
error helps to prevent damages
to the compressor.
-
The voltage needs to be
increased back to required
levels
If this warning continues, contact
the Sharp help desk as soon as
possible.
E09
Freezer compartment
is not cold enough
Likely to occur after long
term power failure.
1. Set the freezer temperature
to a colder value or set Super
Freeze. This should remove
the error code once the
required temperature has been
reached. Keep doors closed
to improve time taken to reach
the correct temperature.
2. Remove any products which
have thawed/defrosted during
this error. They can be used
within a short period of time.
3. Do not add any fresh produce
to the freezer compartment
until the correct temperature
has been reached and the
error is no longer.
If this warning continues, contact
the Sharp help desk as soon as
possible.
E10
Fridge compartment
is not cold enough
Likely to occur after:
-
Long term power failure.
-
Hot food has been left in
the fridge.
1. Set the fridge temperature to
a colder value or set Super
Cool. This should remove the
error code once the required
temperature has been reached.
Keep doors closed to improve
time taken to reach the correct
temperature.
2. Please empty the location
at the front area of air duct
channel holes and avoid
putting food close to the
sensor.
If this warning continues, contact
the Sharp help desk as soon as
possible.
E11
Fridge compartment
is too cold
Various
1. Check is Super Cool mode is
activated
2. Reduce the fridge
compartment temperature
3. Check to see if vents are clear
and not clogged
If this warning continues, contact
the Sharp help desk as soon as
possible.