9 – 1
SJ26NSL
Service Manual
CHAPTER 9.
COOLING UNIT
[1] COOLING UNIT
NOTE: The iron pipe is partly used of this refrigerator. Please note the following points when brazing the iron pipe.
•
Brazing material should be silver brazing rod. (To be equivalent with BAg-20 or BAg-7)
•
Flux should be FB3A type. (It should be non-chlorine type).
•
Place an iron plate or cloth on the base frame to prevent the flux fall.
•
Remove the paint and plating on the pipe by the sandpaper before start repairing.
•
If you cut the iron pipe for repairing, remove the plating on the iron pipe end (20mm) by the sandpaper.
•
Put the flux on silver brazing rod and dry the flux by the flame of the torch, and then start brazing.
•
Remove the flux completely by the wire brush , and wipe off by the cloth after brazing.
•
Leakage inspection should be done when compressor is running.
•
After removing flux, paint the black enamel paint on the brazing part.
*
Copper back condenser is used in some models.Before repairing,check the Back condenser is copper or iron.
Hot pipe L
(Side condenser)
Hot pipe
(DP-condenser)
Hot pipe R
(Side condenser)
Evaporator
Suction pipe
Compressor
Capillary tube
Dryer
Back condenser
S.P connector
Discharge P connector
Dryer connector
Mark: Brazing portion
Mark: Refrigerant flow
Iron pipe
Copper pipe
!"#$% &'$( &#$) &'$* &#$+ &'$, &#-( &#-)
Содержание SJ-A20S-SL
Страница 18: ...6 4 6 CIRCUIT DIAGRAM OF MAIN PWB ...