R-980J
22
Pin No.
Signal
I/O
Description
VARI MODE
ON TIME
OFF TIME
HIGH (100% power)
32 sec.
0 sec.
MED HIGH (approx. 70% power)
24 sec.
8 sec.
MED (approx. 50% power)
18 sec.
14 sec.
MED LOW (approx. 30% power)
12 sec.
20 sec.
LOW (approx. 10% power)
6 sec.
26 sec.
ON
OFF
H : GND
L
ON
OFF
During
cooking
L
GND
H.
(Convection)
A
B
C
H: GND
L
0.12 sec
2.4 sec
1.2 sec
1.2 sec
20 msec.
H : GND
L (-5V)
17
P51
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook
relay(RY2). In HIGH operation, the
signals holds "L" level during micro-
wave cooking and "H" level while
not cooking. In other cooking modes
(MED HIGH, MED, MED LOW,
LOW) the signal turns to "H" level
and "L" level in repetition according
to the power level.
18
P50
OUT
Damper motor relay driving signal.
To turn on and off shut-off relay(RY4).
19
P47
OUT
Heating element driving signal.
To turn on and off shut-off relay(RY3). "L" level
during convection cooking; "H" level otherwise.
During convection cooking, the signal becomes
"H" level when the temperature of the oven cavity
exceeds the predetermined temperature.
20-21
P46-P45
OUT
Terminal not used.
22
P44
OUT
Timing signal output terminal for temperature measurement(OVEN THER-
MISTOR).
"H" level (GND) : Thermistor OPEN timing.
"L" level (-5V) : Temperature measuring timing.(Convection cooking)
23
P43
OUT
Signal to sound buzzer.
A: key touch sound.
B: Completion sound.
C: When the temperature of the oven
cavity reaches the preset tempera-
ture in the preheating mode, or when
the preheating hold time (30 min-
utes) is elapsed.
24
P42
OUT
Timing signal output terminal for temperature measurement(OVEN).
"H" level (GND) : Thermistor OPEN timing.
"L" level (-5V) : Temperature measuring timing.(Convection cooking)
25
INT1
IN
Signal to synchronize LSI with commercial power source freqency.
This is the basic timing for all real time
processing of LSI.
26
P40
IN
Connected to GND.
27
RST
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily
set to "L" level the moment power is applied, at this time the LSI is reset. Thereafter
set at "H" level.
28/29
XCIN/XCOUT
OUT
Terminal not used.
30
XIN
IN
Internal clock oscillation frequency setting input.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit
with respect to XOUT terminal.
31
XOUT
OUT
Internal clock oscillation frequency control output.
Output to control oscillation input of XIN.
32
VSS
IN
Power source voltage: -5V.
VC voltage of power source circuit input.
33
P27
IN
Signal coming from touch key.
When any one of G-1 line keys on key matrix is touched, a corresponding signal
from P17 - P17 will be input into P27. When no key is touched, the signal is held
at "L" level.
34
P26
IN
Signal similar to P27.
When any one of G-2 line key on key matrix is touched, a corresponding signal will
be input into P26.
Содержание R-980J
Страница 2: ...R 980J ...