31
1. CARRY OUT 3D CHECKS.
2. Remove the wire leads as Positive lock
®
connector
removal above.
3. Lift up the oven lamp from its retaining clips by pushing
the tab of the air intake duct.
4. Now, the oven lamp is free.
Figure C-3. Oven lamp
Removal
1. CARRY OUT 3D CHECKS.
2. Remove the one (1) screw holding the green/yellow
wire to the back plate.
3. Disconnect the leads of the power supply cord from the
noise filter, referring to the Figure C-4(a).
4. Release the power supply cord from the rear cabinet.
5. Now, the power supply cord is free.
Re-install
1. Insert the moulding cord stopper of power supply cord
into the square hole of the power angle, referring to the
Figure C-4(b).
2. Install the earth wire lead of power supply cord to the
back plate with one (1) screw and tight the screw.
3. Connect the brown and blue wire leads of power supply
cord to the noise filter correctly, referring to the Pictorial
Diagram.
POWER SUPPLY CORD REPLACEMENT
POSITIVE LOCK
®
CONNECTOR REMOVAL
1. CARRY OUT 3D CHECKS.
2. Push the lever of positive lock
®
connector.
3. Pull down on the positive lock
®
connector.
CAUTION: WHEN YOU (SERVICE ENGINEERS)
CONNECT THE POSITIVE LOCK
®
CON-
NECTORS TO THE TERMINALS, CON-
NECT THE POSITIVE LOCK
®
SO THAT
THE LEVER FACES YOU(SERVICE EN-
GINEERS).
Figure C-2. Positive lock
®
connector
Terminal
Push
Pull down
1
2
Lever
Positive lock®
connector
Figure C-4 (a) Replacement of Power Supply Cord
Figure C-4(b). Power Supply Cord Replacement
OVEN LAMP SOCKET REMOVAL
15.Now, the convection unit assembly is free.
CONVECTION HEATING ELEMENT REMOVAL
15. Remove the two (2) screws holding the convection
heating element to the convection duct.
16. Remove the one (1) screw holding the convection
heater angle to the convection duct.
17. Remove the one (1) screw holding the convection
heater angle and the air separate angle D to the
convection duct.
18. Remove the one (1) screw holding the convection
heater angle A to the convection duct.
19. Remove the convection heating element from the
convection duct.
20. Now, the convection heating element is free.
CONVECTION MOTOR REMOVAL
15. Remove the one (1) nut and washer from the convec-
tion motor shaft.
16. Remove the convection fan from the convection motor
shaft.
17. Remove the pipe from the convection motor shaft.
18. Remove the two (2) screws holding the convection
motor angle to the convection duct.
19. Remove the cooling fan from the convection motor
shaft.
20. Remove the two (2) screws holding the convection
motor to the convection motor angle.
21. Remove the one (1) ring from the convection motor
shaft.
22. Now, the convection motor is free.
Power supply cord
Back plate
Moulding cord stopper
Square hole
;;;
;;
Power supply
cord
Back plate
Blue wire
Brown wire
Green/
Yellow wire
Noise filter
WHIT
RED
F2
F1
TP
N
L
TL
Lock
Socket
Bulb
COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE