ADJUSTMENT OF THERMISTOR SENSOR CIRCUIT
Adjust this circuit if necessary in order to measure the
temperature of food correctly.
1) When readjustment is necessary
The volumes VR30
ohms) and VR31
ohms)
must be readjusted after replacing the parts identified by
asterisk
mark given in circuit diagram is replaced.
2) Method of adjustment
Adjust in the following procedures.
(1) Turn off the power. (Main switch “OFF”)
(2) Connect the checker to the control panel assembly.
(3) Set the rotary switch of checker to
.
43C
(4) Turn on the power (Main switch “ON”) and stop
switch “ON”.
(5) Touch CONVECTION, 250°C and COOK pads.
(Then, the temperature will be displayed)
(6) Rotate the volume VR30 until the indication turns
to
(7) Set the rotary switch of checker to
(147C
If
is not indicated, rotate the volume
VR31 until the indication turns to “147C
(8)
Make sure to indicated “LO C” when set the rotary
switch of checker to
(LO C.)
(9) Make sure the convection cooking operation is
stopped when set the rotary switch of checker to
. .
l
l-l
l
ZD30
I
R113
l z2
A
(LOW) I
I
(HIGH)
THERMISTOR
Figure 28. Thermistor Sensor Circuit
Printed Wiring Board (Control Unit)
97
Содержание R-8320E
Страница 105: ...AIR GUIDE DUCT B m D 4 T B 1 THERMAL PROTECTION PLATE D re 31 Oven Cavity Components Part II 104 ...
Страница 119: ...PRINTED WIRING BOARD CONTROL UNIT P M 0 3 12 1 I To 12 n 118 ...
Страница 121: ...IEL AND RELAY UNIT CIRCUIT i iiiitiii r 1 I I I I I I t L J Cl00 3300 x 7 H Z J STOP SWTCH 120 ...
Страница 122: ...PRINTED WIRING BOARD RELAY UNIT t 121 ...
Страница 133: ...CABINET PARTS 0 7 2 132 ...
Страница 134: ...0 4 4 0 4 l 133 ...
Страница 135: ...134 ...
Страница 136: ...OVEN PARTS II I k5 rI f 135 ...
Страница 137: ...136 ...
Страница 138: ...CONTROL PANEL PARTS 3 3 P 0 0 J I I f I I I I II II I 3 l 0P 0 7 i J a 81 J Y0 3 5 137 ...
Страница 139: ...DOOR ASSEMBLY I MISCELLANEOUS Tra Capa Mag 138 ...