R-64ST - 31
Parts
Symbol
Value / Data
Fuse
F1
F8A
Fuse
F2
20A
Thermostat (HVT.)
TC1
15
0
°
C OFF 96
°
C ON
Thermostate (OVEN)
TC2
150
°
C OFF 130
°
C ON
Grill heating element
GH
Approx. 27.9
Ω
x 2 = 55.8
Ω
, 1.0 kW (500W x 2)
Insulation resistance > 10 M
Ω
Oven lamp
OL
240–250 V 25W
High voltage capacitor
C
AC 2100V 0.97
µ
F
Magnetron
MG
Filament < 1
Ω
Filament – chassis
∞
ohm.
Power transformer
T
Filament winding < 1
Ω
Secondary winding Approx. 142
Ω
/ Primary winding Approx. 2
Ω
TEST POINTS ON CONTROL UNIT
Resistance (Disconnect the
In/Out put terminal
Test Point
Volt
powerand door is closed)
Input terminal (Power supply)
A1 - A3
230 V
Approx. 1.04 k
Ω
Input terminal (Stop switch)
B1 - B2
-
0
Output terminal (Grill heating element)
NO. of RY2 - A3
230 V
Approx. 370
Ω
Output terminal
(Oven lamp, fan motor and turntable motor)
A3 - A5
230 V
Approx. 180
Ω
Output terminal (Earth)
B2 - Chassis
-
0
Output terminal (High voltage transformer)
NO. of RY3 - A3
230V
Approx. 370
Ω
WARNING: DISCONNECT THE PLUG WHEN MEASURING RESISTANCE.
TEST DATA AT A GLANCE
RE-WIRING
Ensure the following:
1.
Wires must not touch:
a)
High voltage parts.
(Magnetron, high voltage transformer, high voltage capacitor and high voltage rectifier assembly)
b)
Parts that become hot.
(Heating elements, oven lamp, oven cavity magnetron and high voltage transformer)
c)
Sharp edges.
(Bottom plates, oven cavity, waveguide flange, chassis support and other metallic parts)
d)
Movable parts.
(Fan blade, any motor, switch, switch lever and open button)
2.
Positive lock connectors are fitted correctly. Ensure the locking pin is located correctly.
3.
Wires are connected correctly as per pictorial diagram.
4.
No wire leads are trapped by the outer wrap.
WARNING:
Before carrying out any work carry out 3D checks
1)
D
isconnect the supply.
2)
D
oor opened, and wedged open.
3)
D
ischarge high voltage capacitor.
WIRING / RE-WIRING
R64ST_S.MANUAL
12/8/01, 11:01 am
31