22
R- 630DK
R-630DW
R -630 DS
23
P24
OUT
Oven lamp, fan motor and turntable motor driving signal
To turn on and off shut off relay (RY1). The
square waveform voltage is delivered to the
RY1 driving circuit and RY2 control circuit.
24
P25
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay (RY2). The
signals holds "L" level during microwave cook-
ing and "H" level while not cooking. In other
cooking modes (variable cooking) the signal
turns to "H" level and "L" level in repetition
according to the power level.
(ON and OFF times for other power level.)
25
P26
OUT
Back light (Light emitting diodes) circuit driving signal.
26
P27
OUT
Terminal not used.
27-29
P30-P32
OUT
Terminal not used.
30-34
P33-P37
OUT
Used for initial balancing of the bridge circuit (absolute humidity sensor).
35
CVCC
IN
Power source voltage: GND(0V).
The power source voltage to drive LSI is input to CVCC terminal. Connected to GND.
36
VSS
IN
Power source voltage: -5.0V.
The power source voltage to the LSI is input to VSS terminal. Connected to VC.
37-38
V3-V2
IN
Terminal not used.
39-40
V1-V0
IN
Power source voltage input terminal.
Standard voltage for LCD. Connected to GND.
41
VCC
IN
Power source voltage : GND(0V).
The power source voltage to drive LSI is input to VCC terminal.
42-45
COM4-COM1
OUT
Terminal not used.
46-65
SEG1-SEG20
OUT
Terminal not used.
66-69
P74-P77
OUT
Data output terminal to LCD driver IC3.
70-77
P80-P87
OUT
Data output terminal to LCD driver IC3.
78-79
P90-P91
OUT
Data output terminal to LCD driver IC3.
80-85
SEG35-SEG40
OUT
Terminal not used.
86-88
P40-P42
OUT
Terminal not used.
89
IRQ0
IN
Signal synchronized with commercial power source frequency.
This is the basic timing for time processing of LSI.
90
AVCC
IN
A/D converter power source voltage : GND(0V).
The power source voltage to drive the A/D converter. Connected to GND.
91
AN0
IN
Used for initial balancing of the bridge circuit (absolute humidity sensor). This input is an
analog input terminal from the AH sensor circuit, and connected to the A/D converter built
into the LSI.
92
AN1
IN
AH sensor input.
This input is an analog input terminal from the AH sensor circuit, and connected to the
A/D converter built into the LSI.
93
AN2
IN
To input signal which communicates the door open/close information to LSI.
Door close "H" level signal (0V). Door open "L" level signal (-5V).
94
AN3
IN
Connected to VC through the pull-down resistor.
Pin No.
Signal
I/O
Description
16.7 msec.
During cooking
H : GND
L : -5V
100
PERCENT
70
PERCENT
H : GND
L : -5V
H : GND
L : -5V
ON
ON
OFF
OFF
OFF
24 sec.
8 sec.
16.7 msec.
H : GND
L : -5V