24
SEC R55TS
TINSEA983WRRZ-D32 SEC R55TS
Please check the following before calling for service:
1. Place one cup of water in a glass measuring cup in the oven and close the door securely.
Operate the oven for one minute at MICRO 100%.
A
Does the oven light come on?
YES
_______
NO _______
B
Does the cooling fan work?
YES
_______
NO _______
(Put your hand over the rear ventilating openings.)
C
Does the turntable rotate?
YES
_______
NO _______
(It is normal for the turntable to turn in either direction.)
D
Is the water in the oven warm?
YES
_______
NO _______
2. Remove water from the oven and operate the oven for 5 minutes at BAKE 400°F.
A Do HEATER and COOK indicators light? YES
_______
NO _______
B After the oven shuts off, is inside of the oven hot? YES
_______
NO _______
If “NO” is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit breaker.
If they are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER.
A microwave oven should never be serviced by a “do-it-yourself” repair person.
NOTE:
1. If time appearing in the display is counting down very rapidly, check DEMONSTRATION MODE on page
22 and cancel.
2. If the oven is set for more than 20 minutes at MICRO 100 percent power level, after the first 20 minutes
the power level will automatically adjust to 70 percent power to avoid overcooking.
3. This oven adjusts GRILL, BAKE and AUTOMATIC COOKING by turning the top and bottom heaters on
and off. It is normal to observe the top heater change from red to dark gray.
4. After cooking is completed, the cooling fan may run for a short time to lower the temperature.
S E R V I C E C A L L C H E C K
★
The International Electrotechnical Commission’s standardized method for measuring output wattage. This test
method is widely recognized.
★★
Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding
food is less.
In compliance with standards set by:
FCC
–
Federal Communications Commission Authorized.
DHHS
–
Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I,
Subchapter J.
–
This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
S P E C I F I C A T I O N S
Single phase 120V, 60Hz, AC only
980 W 8.5A
1300W 10.8 A
650 W* (IEC Test Procedure)
760 W
510 W
2450 MHz
17-3/4"(W) x 11-3/8"(H) x 15-1/8"(D)
11-1/4"(W) x 5-7/8"(H) x 11-5/8"(D)
Approx. 0.5 Cu. Ft.
Turntable system, 10
1
/
2
" diameter
Approx. 31lb
AC Line Voltage:
AC Power Required:
Microwave
Grill/Bake
Output Power:
Microwave
Top heater
Bottom heater
Frequency:
Outside Dimensions:
Cavity Dimensions
★★
:
Oven Capacity
★★
:
Cooking Uniformity:
Weight: