H

BLOWN MONITOR FUSE TEST

TEST PROCEDURES

PROCEDURE

LETTER

COMPONENT TEST

1. Disconnect the power supply cord, and then remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. If the monitor fuse is blown when the door is opened, check the primary interlock relay, secondary

interlock switch and monitor switch according to the "TEST PROCEDURE" for those switches before
replacing the blown monitor fuse.

CAUTION: BEFORE REPLACING A BLOWN MONITOR FUSE, TEST THE PRIMARY INTERLOCK

RELAY, SECONDARY INTERLOCK SWITCH, DOOR SENSING SWITCH AND MONITOR
SWITCH FOR PROPER OPERATION.

If the monitor fuse  is blown by improper switch operation, the monitor fuse and monitor switch must
be replaced with "monitor fuse and monitor switch assembly" part number FFS-BA016/KIT, even if the
monitor switch operates normally. The monitor fuse and monitor switch assembly is comprised of a
20 ampere fuse and switch.

5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all functions.

The touch control panel consists of circuits including semiconductors such as LSI, ICs, etc. Therefore,
unlike conventional microwave ovens, proper maintenance cannot be performed with only a voltmeter
and ohmmeter. In this service manual, the touch control panel assembly is divided into two units, Control
Unit and Key Unit, and also the Control Unit is divided into two units, LSI Unit and Power Unit, and
troubleshooting by unit replacement is described according to the symptoms indicated.
Before testing,
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Disconnect the leads to the primary of the power transformer.
5) Ensure that these leads remain isolated from other components and oven chassis by using insulation tape.
6) After that procedure, re-connect the power supply cord.
1. Key Unit.

NOTE ;
1) Disconnect the power supply cord, and then remove outer case.
2) Open the door and block it open.
3) Discharge high voltage capacitor.
4) Check Key unit ribbon connection before replacement.
5) Reconnect all leads removed from components during testing.
6) Re-install the outer case (cabinet).
7) Reconnect the power supply cord after the outer case is installed.
8) Run the oven and check all functions.

I

TOUCH CONTROL PANEL ASSEMBLY TEST

5. Reconnect all leads removed from components during testing.
6. Reinstall the outer case (cabinet).
7. Reconnect the power supply cord after the outer case is installed.
8. Run the oven and check all

functions.

Monitor 
Switch

Secondary Interlock Switch

Screw Driver

Ohmmeter

RED

WHT/WHT

Содержание R-430CD

Страница 1: ...LE EXPOSURE TO EXCESSIVE MICROWAVE ENERGY INSIDE FRONT COVER BEFORE SERVICING INSIDE FRONT COVER WARNING TO SERVICE PERSONNEL 1 MICROWAVE MEASUREMENT PROCEDURE 2 FOREWORD AND WARNING 3 PRODUCT SPECIFICATIONS 4 GENERAL INFORMATION 5 OPERATION 6 TROUBLESHOOTING GUIDE 10 TEST PROCEDURE 12 TOUCH CONTROL PANEL 21 COMPONENT REPLACEMENT AND ADJUSTMENT PROCEDURE 25 PICTORIAL DIAGRAM 33 POWER UNIT CIRCUIT ...

Страница 2: ...neration and transmission systems shall be repaired replaced or adjusted by procedures described in this manual before the oven is released to the owner e A microwave leakage check to verify compliance with the Federal Performance Standard should be performed on each oven prior to release to the owner BEFORE SERVICING Before servicing an operative unit perform a microwave emission check as per the...

Страница 3: ...ltage capacitor 4 Disconnect the leads to the primary of the power transformer 5 Ensure that the leads remain isolated from other components and oven chassis by using insulation tape 6 After that procedure reconnect the power supply cord When the testing is completed 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capacitor 4...

Страница 4: ...n the center of the oven cavity The water container shall be a low form of 600 ml 20 oz beaker with an inside diameter of approx 8 5 cm 3 1 2 in and made of an electrically nonconductive material such as glass or plastic The placing of this standard load in the oven is important not only to protect the oven but also to insure that any leakage is measured accurately 4 Set the cooking control on Ful...

Страница 5: ...door packing is not damaged D The door is not deformed or warped E There is no other visible damage with the oven Servicing and repair work must be carried out only by trained service personnel DANGER Certaininitialpartsareintentionallynotgroundedandpresent a risk of electrical shock only during servicing Service personnel Do not contact the following parts while the appliance is energized HighVol...

Страница 6: ...Pad Number Selection Pad Kitchen Timer Pad Clock pad Minute Plus Pad Power Level Pad Stop Clear Pad Start Touch on Pad Oven Cavity Light Safety Standard UL Listed FCC Authorized DHHS Rules CFR Title 21 Chapter 1 Subchapter J SPECIFICATION GENERAL INFORMATION GROUNDING INSTRUCTIONS This oven is equipped with a three prong grounding plug It must be plugged into a wall receptacle that is properly ins...

Страница 7: ...CES CUT OR RE MOVE THE ROUND GROUNDING PRONG FROM THIS PLUG OVEN DIAGRAM 1 One touch door open button Push to open door 2 Door latches The oven will not operate unless the door is securely closed 3 Removable turntable support 4 Removable turntable The turntable will rotate clockwise or counterclockwise 5 Oven lamp It will light when oven is operating or door is opened 6 Oven door with see through ...

Страница 8: ...cuits to the turntable motor the cooling fan motor and the high voltage components are de energized the oven lamp remains on and the digital read out displays the time still remaining in the cook cycle when the door was opened 7 The monitor switch electrically monitors the operation of the secondary interlock switch and primary interlock relayandismechanicallyassociatedwiththedoorsothat it will fu...

Страница 9: ... one of the SENSOR pads NOTE The oven should not be operated on sensor immediatly after plugging in the unit Wait two minutes before cooking on SENSOR 2 The coil of shut off relay RY 1 is energized the turntablemotorareturnedon butthepowertransformer is not turned on 3 After about 16 seconds the cook relay RY 2 is energized The power transformer is turned on microwaveenergyisproducedandfirststagei...

Страница 10: ... INTERLOCK RELAY B1 B2 GRN POWER TRANSFORMER MONITOR FUSE 20A MAGNETRON TEMP FUSE CAPACITOR 1 0µF AC 2300V AH SENSOR 120V AC 60 Hz OVEN LAMP TURN TABLE MOTOR FAN MOTOR MONITOR SWITCH H V RECTIFIER MAGNETRON SECONDARY INTERLOCK SWITCH TTM OL FM CAVITY TEMP FUSE A1 A2 COM COM COM N O N C N O DOOR SENSING SWITCH RY 1 RY 2 CONTROL UNIT PRIMARY INTERLOCK RELAY B1 B2 GRN POWER TRANSFORMER MONITOR FUSE 2...

Страница 11: ...REPLACING A BLOWN MONITOR FUSE TEST THE DOOR SENSING SWITCH PRIMARY INTERLOCK RELAY RY2 RELAY RY1 SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH FOR PROPER OP ERATION REFERTOCHAPTER TESTPRO CEDURE NOTE MONITOR FUSE AND MONITOR SWITCH ARE REPLACED AS AN ASSEMBLY TURNTABLE MOTOR The turntable motor rotates the turntable located on the bottom of the oven cavity so that the foods on the turntable cook ...

Страница 12: ...t FFS BA016 KIT as an assembly IMPORTANT Whenever troubleshooting is performed with the power supply cord disconnected It may in some cases be necessary to connect the power supply cord after the outer case has been removed in this event 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capacitor 4 Disconnect the leads to the p...

Страница 13: ...ok cycle Oven goes into a cook cycle but extremely uneven heating is produced in oven load food Oven does not cook properly when programmed for Cooking Power 5 mode Operates properly on Cooking Power 10 HIGH mode Oven goes into COMPU DEFROST but food is not defrosted well AH sensor does not end during sensor cooking condition Oven does not shut off after a cup of water is boiling by sensor cooking...

Страница 14: ...SO EXTREME CAUTION SHOULD BE OBSERVED Power output of the magnetron can be measured by performing a water temperature rise test This test shouldonlybeusedifabovetestsdonotindicateafaultymagnetronandthereisnodefectinthefollowing componentsorwiring siliconrectifier highvoltagecapacitorandpowertransformer Thistestwillrequire a 16 ounce 453cc measuring cup and an accurate mercury thermometer or thermo...

Страница 15: ...ecially the cooling fan and air guide 5 Reconnect all leads removed from components during testing 6 Reinstall the outer case cabinet 7 Reconnect the power supply cord after the outer case is installed 8 Run the oven and check all functions MAGNETRON TEMPERATURE FUSE TEST 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capaci...

Страница 16: ...y interlock switch 5 Reconnect all leads removed from components during testing 6 Reinstall the outer case cabinet 7 Reconnect the power supply cord after the outer case is installed 8 Run the oven and check all functions PRIMARY INTERLOCK SYSTEM TEST DOOR SENSING SWITCH 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capacit...

Страница 17: ... microwave ovens proper maintenance cannot be performed with only a voltmeter and ohmmeter In this service manual the touch control panel assembly is divided into two units Control Unit and Key Unit and also the Control Unit is divided into two units LSI Unit and Power Unit and troubleshooting by unit replacement is described according to the symptoms indicated Before testing 1 Disconnect the powe...

Страница 18: ... Clock does not operate properly c Cooking is not possible When testing is completed 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capacitor 4 Reconnect all leads removed from components during testing 5 Re install the outer case cabinet 6 Reconnect the power supply cord after the outer case is installed 7 Run the oven and ...

Страница 19: ...rol unit with an A C voltmeter The meter should indicate 120 volts if not check oven circuit RY1 and RY2 Relay Test These relays are operated by D C voltage Check voltage at the relay coil with a D C voltmeter during the microwave cooking operation DC voltage indicated Defective relay DC voltage not indicated Check diode which is connected to the relay coil If diode is good control unit is defecti...

Страница 20: ...ord after the outer case is installed 9 Run the oven and check all functions 2 Followthetroubleshootingguidegivenbelow ifindicatordoesnotlightupafterabovecheckandrepairs are finished 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Discharge high voltage capacitor 4 Disconnect the leads to the primary of the power transformer 5 Ensure that these lea...

Страница 21: ...tap water in 1000 milliliters measuring cup 3 Place the container on the center of tray in the oven cavity 4 Close the door 5 Touch SENSOR REHEAT pad once and touch the start pad Now the oven is in the sensor cooking condition SENSOR REHEAT will appear in the display 6 The oven will operate for the first 16 seconds without generating microwave energy NOTE ERROR will appear if the door is opened or...

Страница 22: ... seconds push plunger of select switch for more than 3 seconds This condition is same as judgementc by AH sensor 9 4 After approximately 3 seconds the display shows xx xx which is remaining cooking time and the display count down If the above is not the case the control unit is probably defective If the above is proper the AH sensor is probably defective 10 Disconnect the power supply cord and the...

Страница 23: ... light the oven lamp 5 Buzzer Circuit The buzzer is responsive to signals from the LSI to emit audiblesounds keytouchsoundandcompletionsound 6 Synchronizing Signal Circuit The power source synchronizing signal is available in order to compose a basic standard time in the clock circuit It accompanies a very small error because it works on commercial frequency 7 Door Sensing Switch A switch to tell ...

Страница 24: ...trix is touched 12 X1 IN Connected to GND 13 X2 OUT Terminal not used 14 VSS IN Power source voltage 5 0V VC voltage of power source circuit input 15 OSC2 OUT Internal clock oscillation frequency control output Output to control oscillation input of OSC2 16 OSC1 IN Internal clock oscillation frequency input setting The internal clock frequency is set by inserting the ceramic filter oscillation cir...

Страница 25: ...ed 46 65 SEG1 SEG20 OUT Terminal not used 66 79 P74 P91 OUT Data output terminal to LCD driver IC3 80 85 SEG35 SEG40 OUT Terminal not used 86 P40 OUT Terminal not used 87 P41 IN Signal similar to AN10 When either G13 line on key matrix is touched a corresponding signal will be input into P41 88 P42 INSignal similar to AN10 When either G12 line on key matrix is touched a corresponding signal will b...

Страница 26: ... cooking input according to the Model ByusingtheA DconvertercontainedintheLSI DCvoltageinaccordancewiththeModel in operation is applied to set up its cooking constant 99 AN8 IN Input terminal to judge the model The signal will be input into AN8 through one of G1 G8 lines on key matrix The LSI will judge the model by this signal 100 P41 IN Signal similar to AN10 WheneitherG11lineonkeymatrixistouche...

Страница 27: ...control sensor cooking of the unit When the unit is set in the sensor cooking mode 16 seconds clearing cycle occurs then the detector circuit starts to function and the LSI observes the initial voltage available at its AN1 terminal With this voltage given the switches SW1 to SW5 in the LSI are turned on in such a way as to change the resistance values in parallel with R107 R111 of IC2 Changing the...

Страница 28: ...t to the oven door being closed Connect an external power source to the power input terminal of the touch control panel then it is possible to check and repair the controls of the touch control panel it is also possible to check the sensor related controls of the touch control panel by using the dummy resistor s 3 Servicing Tools Toolsrequiredtoservicethetouchcontrolpanelassembly 1 Soldering iron ...

Страница 29: ...WIRING 1 Disconnect the power supply cord 2 Make sure that a definite click can be heard when the microwave oven door is unlatched Hold the door in a closed position with one hand then push the door open button with the other this causes the latch leads to rise it is then possible to hear a click as the door switches operate 3 Visuallycheckthedoorandcavityfaceplatefordamage dents cracks signs of a...

Страница 30: ...ment lead short one of the power transformer from the high voltage capacitor 7 Remove one 1 screw holding capacitor holder with the high voltage rectifier to the base plate 8 Disconnect rectifier terminal from capacitor High voltage rectifier assembly is now free 9 Remove capacitor holder Capacitor is now free CAUTION WHEN REPLACING HIGH VOLTAGE RECTI FIER AND HIGH VOLTAGE CAPACITOR GROUND SIDE TE...

Страница 31: ... with soft cloth not to scratch LSI UNIT NOTE Handle the LSI unit carefully so that there is no excessive force applied to the ribbon connection LSI unit 1 Disconnect the power supply cord 2 Removeturntableandturntablesupportfromovencavity 3 Lay the oven on it s backside Remove the turntable motor cover by snipping off the material in four corners 4 Where the corners have been snipped off bend cor...

Страница 32: ... the bracket may be disfigured Make sure that the fan blade rotates smooth after installation Make sure that the axis of the shaft is not slanted 5 Install the fan motor to the the oven cavity back plate with the two 2 screws 6 Connect the wire leads to the fan motor referring to the pictorial diagram Side View Rear View 1 Disconnect the power supply cord and remove outer case 2 Open the door and ...

Страница 33: ... in the door should be less than 0 5mm 2 The door sensing switch and secondary interlock switch interrupt the circuit before the door can be opened 3 Monitor switch contacts close when door is opened 4 Re install outer case and check for microwave leakage around door with an approved microwave survey meter Refer to Microwave Measurement Procedure DOOR REPLACEMENT REMOVAL 1 Disconnect the power sup...

Страница 34: ...ce pressed toward cavity face plate 4 Check for microwave leakage around door with an approvedmicrowavesurveymeter RefertoMicrowave Measurement Procedure Note The door on a microwave oven is designed to act as an electronic seal preventing the leakage of microwave energy from oven cavity during cook cycle Thisfunctiondoesnotrequirethatdoorbeair tight moisture condensation tight or light tight Ther...

Страница 35: ...n light socket POWER TRANSFORMER COM NO NOTE The neutral WHT GRY wire must be connected to the terminal with N mark on the power supply cord RED WHT BRN RED WHT WHT ORG WHT RED BLK RED BLU PNK GRN GRN to Oven cavity WHT WHT RED BLK WHT WHT BLUE MARK WHT RED WHT CAVITY TEMP FUSE MAGNETRON TEMP FUSE FAN MOTOR MONITOR FUSE HOLDER RED RED WHT 1 WHT GRY WHT ORG BLU GRN ORG ORG RY2 RY1 PRIMARY INTERLOCK...

Страница 36: ...34 R 430CK R 430CW R 430CD 6 4 5 1 2 3 6 4 5 1 2 3 A B C D E F G H A B C D E F G H Figure S 2 Power Unit Circuit ...

Страница 37: ...35 R 430CK R 430CW R 430CD 6 4 5 1 2 3 6 4 5 1 2 3 A B C D E F G H A B C D E F G H Figure S 3 CPU Unit Circuit ...

Страница 38: ...36 R 4 3 0 C K R 430CW R 4 3 0 C D 6 4 5 1 2 3 6 4 5 1 2 3 A B C D E F G H A B C D E F G H Figure Indicator circuit ...

Страница 39: ...37 R 430CK R 430CW R 430CD 6 4 5 1 2 3 6 4 5 1 2 3 A B C D E F G H A B C D E F G H Figure S 5 Printed Wiring Board of Power Unit ...

Страница 40: ...FW VZB146MRE0 M 12Pin wire harness CN C 1 AG C1 RC KZA087DRE0 J Capacitor 0 1 uF 50V 1 AA C2 VCEAB31VW108M J Capacitor 1000 uF 35V 1 AF C3 RC KZA087DRE0 J Capacitor 0 1 uF 50V 1 AA C4 5 VCEAB31VW106M J Capacitor 10 uF 35V 1 AF D1 4 VHD11ES1 1 J Diode 11ES1 4 AB D5 8 VHD1SS270A 1 J Diod e 1SS270ATA 4 AA Q1 2 VS2SB1238 3 J Transistor 2SB1238 2 AA Q3 VSKRC243M 3 J Transistor KRC243M 1 AB R1 VRD B12EF...

Страница 41: ...M Door screen R 430CD 1 AM MISCELLANEOUS 6 1 FW VZB125MRE0 M Stop switch harnnes 1 AF 6 2 FW VZB168MRE0 M Main wire harnnes 1 AU 6 3 QW QZB016MRE0 M High voltage wire A 1 AC 6 4 FROLPB025MRK0 M Turntable support 1 AN 6 5 NTNT A095WRE0 M Turntable tray 1 AM 6 6 TCAUAB037MRR0 M Monitor caution label 1 AA 6 7 TCAUAB038MRR0 M DHHS Screw caution label 1 AB 6 8 TINSEB206MRR0 M Operation manual 1 AD 6 9 ...

Страница 42: ...G H A B C D E F G H OVEN AND CABINET PARTS 2 3 4 7 6 7 1 5 4 6 4 8 4 9 6 5 6 4 2 1 7 6 1 12 4 10 7 2 7 2 7 5 4 3 1 13 7 3 7 6 1 9 7 8 7 8 4 2 7 5 1 11 1 3 1 4 7 4 1 8 1 8 4 4 7 1 4 1 1 1 1 2 2 2 2 2 2 2 2 2 7 5 7 5 4 12 7 5 6 6 1 7 1 6 4 5 1 14 7 7 7 7 7 9 7 9 7 10 ...

Страница 43: ...1 2 3 6 4 5 1 2 3 A B C D E F G H A B C D E F G H CONTROL PANEL PARTS 5 1 5 1 2 5 1 1 5 3 5 4 5 5 5 2 Actual wire harness may be different from illustration 6 3 6 2 6 1 DOOR PARTS MISCELLANEOUS 3 3 3 2 3 2 1 3 2 4 3 2 5 3 2 2 3 2 3 3 1 ...

Страница 44: ... ACCESSORIES Non replaceable items DOOR PROTECTION SHEET PLASTIC BAG PACKING CASE TOP PAD ASSEMBLY INTO THE OVEN CAVITY 6 5 TURNTABLE TRAY 6 4 TURNTABLE SUPPORT 6 8 OPERATION MANUAL TRAY PACK BOTTOM PAD ASSEMBLY TRAY HOLDER 6 9 RECIPE CARD ...

Страница 45: ...GHT 1999 BY SHARP CORPORATION ALL RIGHTS RESERVED No part of this publication may be repro duced stored in retrieval systems or trans mitted in any form or by any means elec tronic mechanical photocopying recording orotherwise withoutpriorwrittenpermission of the publisher ...

Отзывы: