30
R - 4 2 0 C K
R-420CW
COOLING FAN MOTOR REMOVAL
REMOVAL
1. Disconnect the power supply cord and then remove outer
case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the wire leads from the fan motor.
5. Remove the two (2) screws holding the fan motor to the
oven cavity back plate.
6. Remove the fan blade from the fan motor shaft according
to the following procedure.
7. Hold the edge of the rotor of the fan motor by using a pair
of groove joint pliers.
CAUTION:
*
Make sure that no metal pieces enter the gap between
the rotor and the stator of the fan motor because the
rotor is easily shaven by pliers and metal pieces may
be produced.
*
Do not touch the pliers to the coil of the fan motor
because the coil may be cut or injured.
*
Do not disfigure the bracket by touching with the
pliers.
8. Remove the fan blade from the shaft of the fan motor by
pulling and rotating the fan blade with your hand.
9. Now, the fan blade and the fan motor will be free.
CAUTION:
*
Do not reuse the removed fan blade because the hole
(for shaft) may be larger than normal.
INSTALLATION
1. Install the fan blade to the fan motor shaft according to the
following procedure.
2. Hold the center of the bracket which supports the shaft of
the fan motor on the flat table.
3. Apply the screw lock tight into the hole (for shaft) of the
fan blade.
4. Install the fan blade to the shaft of fan motor by pushing
the fan blade with a small, light weight, ball peen hammer
or rubber mallet.
CAUTION:
*
Do not hit the fan blade strongly when installed
because the bracket may be disfigured.
*
Make sure that the fan blade rotates smooth after
installation.
*
Make sure that the axis of the shaft is not slanted.
5. Install the fan motor to the oven cavity back plate with the
two (2) screws.
6. Connect the wire leads to the fan motor, referring to the
pictorial diagram.
Side View
Rear View
1. Disconnect the power supply cord and remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect wire leads from the switches.
5. Remove two (2) screws holding latch hook to oven flange.
6. Remove latch hook assembly from oven flange.
7. Push outward on the two (2) retaining tabs holding switch
in place.
8. Switch is now free.
At this time switch lever will be free, do not lose it.
Re-install
1. Re-install each switch in its place. The secondary interlock/
monitor switches are in the lower position and the door
sensing switch is in the upper position.
2. Re-connect wire leads to each switch.
Refer to pictorial diagram.
DOOR SENSING SWITCH/SECONDARY INTERLOCK SWITCH AND MONITOR SWITCH REMOVAL
AH SENSOR REPLACEMENT
REMOVAL
1. Disconnect the power supply cord and remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Remove the two (2) screws holding the AH sensor to the
sensor duct.
5. Disconnect the AH sensor harness from the connector
CN-F on control unit.
6. AH sensor is now free
RE-INSTALL
1. Insert the new AH sensor into the sensor duct.
2. Install two (2) screws to secure the AH sensor.
3. Route the AH sensor harness across the oven cavity top
plate and through the large opening.
4. Connect the AH sensor harness to CN-F on control unit.
5. Re-install the outer case cabinet and check for proper
operation.