24
R-308DW
R -310 DK
R-310DW
CONTROL PANEL ASSEMBLY REMOVAL
OVEN LAMP AND LAMP SOCKET REMOVAL
1. Disconnect the power supply cord and remove outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Remove the oven lamp from the oven lamp socket.
5. Pull the wire leads from the oven lamp socket by pushing
the terminal hole of the oven lamp socket with the small
flat type screw driver.
6. Bend the tab of the partition angle holding the lamp
socket.
7. Lift up the oven lamp socket.
8. Now, the oven lamp socket is free.
POSITIVE LOCK
®
CONNECTOR (NO-CASE TYPE) REMOVAL
Figure C-2. Positive lock
®
connector
1. Disconnect the power supply cord, and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Push the lever of positive lock
®
connector.
5. Pull down on the positive lock
®
connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK
®
CONNECTORS TO THE TERMINALS, CON-
NECT THE POSITIVE LOCK
®
SO THAT THE
LEVER FACES YOU
is not hit by any metal object around antenna.
10.Remove the two (2) screws holding the magnetron duct
to magnetron.
11.Remove the magnetron duct with thermal cut-out (MG)
from magnetron.
12.Now, the magnetron is free.
Re-install
1. Re-install the magnetron duct with thermal cut-out (MG)
to magnetron with the two (2) screws.
2. Re-install the magnetron to waveguide flange with the
four (4) screws.
3. Insert the two (2) tabs of the chassis support to the oven
cavity front plate and the back plate.
4. Hold the chassis support to the oven cavity back plate,
oven cavity front flang, magnetron and the fan duct with
the four (4) screws.
5. Reconnect the wire leads to the magnetron and thermal
cut-out (MG). Refer to "PICTORIAL DIAGRAM" on page
28
.
6. Re-install outer case and check that the oven is operating
properly.
CAUTION: WHEN REPLACING MAGNETRON, BE SURE
THE R.F. GASKET IS IN PLACE AND MOUNT-
ING SCREWS ARE TIGHTENED SECURELY
1. Disconnect the power supply cord and then remove
outer case.
2. Open the door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect wire leads from the door sensing switch and
the oven cavity front flange.
5. Disconnect the wire leads from panel components.
6. Make one (1) tab of the oven cavity front plate straight
holding the control panel assembly to the oven flange.
7. Slide the control panel assembly upward and remove it.
8. Now, individual components can be removed.
NOTE: 1. Before attaching a new key unit, wipe off remaining
adhesive on the control panel frame surfaces
completely with a soft cloth soaked in alcohol.
2. When attaching the key unit to the control panel
frame, adjust the upper edge and right edge of
the key unit to the correct position of control panel
frame.
3. Stick the key unit firmly to the control panel frame
by rubbing with soft cloth not to scratch.
CPU UNIT
NOTE: Handle the CPU unit carefully so that the ribbon
cable does not come off. Because the ribbon cable
is glued on the LCD and the printed wiring board
only by heated paste.
Figure C-1. Oven lamp socket
Oven lamp
socket
Terminal
Wire lead
Terminal hole
Flat type small
screw driver
Terminal
Push
Pull down
1
2
Lever
Positive lock®
connector
Printed wiring board
of CPU unit
Liquid Crystal
Display (LCD)
Ribbon cable