4
R-22GV
R-22GT
R-23GT
R-24GT
SPECIFICATION
ITEM
DESCRIPTION
Power Requirements
120 Volts / 2.0 KW (R-22GV, R-22GT)
Approx. 17.7A
230/208 Volts / 2.5 kW (R-23GT)
Approx. 13A at 208V, 11.9A at 230V
230/208 Volts / 2.9 kW (R-24GT)
Approx. 14 A at 208V, 13.2A at 230V
60 Hertz / Single phase, 3 wire grounded
Power Output
1200 W (R-22GV, R-22GT)/ 1600 W (R-23GT)/ 1800 W (R-24GT)
(IEC-705 TEST PROCEDURE) Operating frequency of 2450MHz
Case Dimensions
Width 20-1/8"
Height 13-1/4"
Depth 18-1/2"
Cooking Cavity Dimensions
Width 13"
Height 7-1/8"
Depth 13"
Control Complement
Touch Control System
Digital Display
10 Number Pads
STOP/CLEAR pad
START pad
SELECTAPOWER pad (Power level: 0 to 100%; except R-22GV)
SELECTATIME pad
DOUBLE QUANTITY pad
EXPRESS DEFROST pad
Memory SET pad
Memory CHECK pad
SIGNAL pad
Weight
Approx. 57 lbs/ 26 kg (R-22GV, R-22GT)/ Approx. 63 lbs/ 29 kg (R-23GT)
Approx. 66 lbs/ 30 kg (R-24GT)
Safety Standard
UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J
NSF Certified
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by
providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a
grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING: Improper use of the grounding plug can result in a risk of electric shock. The electrical requirements are 120
Volt, 60 Hz AC only, 20 Amp or more (R-22GV,R-22GT); 230/208 Volt, 60 Hz, AC only, 15 Amp or more (R-
23GT) and 20 Amp or more (R-24GT) fused electrical supply. It is recommended that a separate circuit serving
only this appliance be provided. When installing this appliance, observe all applicable codes and ordinances.
If it is necessary to use an extension cord, use only a 3-wire extension cord that has a 3-blade grounding plug
and a 3-slot receptacle that will accept the plug on the appliance. The marked rating of the extension cord should
be AC 120 Volt 20 Amp (R-22GV,R-22GT), AC 230/208 Volt 15 Amp (R-23GT), AC230/208 Volt 20 Amp (R-
24GT).
Receptacle Box Cover
3-Pronged plug
(6-15P)
3-Pronged, Receptacle
(6-20R)
Receptacle Box Cover
3-Pronged plug
(6-15P)
3-Pronged, Receptacle
(6-15R)
Receptacle Box Cover
3-Pronged plug
(5-20P)
3-Pronged, Receptacle
(5-20R)
230/208V15A
R-23GT
230/208V20A
R-24GT
120V 20A
R-22GV, R-22GT