R21LCF
11 – 1
R21LCF
Service Manual
CHAPTER 11.
COMPONENT REPLACEMENT AND ADJUSTMENT PROCE-
DURE
[1] WARNING
Please refer to “OVEN PARTS, CABINET PARTS, CONTROL PANEL PARTS, DOOR PARTS”, when carrying out any of the following removal proce-
dures:
[2] OUTER CASE REMOVAL
To remove the outer case, procedure as follows.
1. Disconnect the power supply cord.
2. Open the oven door and block it open.
3. Remove the five (5) screws from rear and along the side edge of
case.
4. Slide the entire case back about 3cm to free it from retaining clips
on the cavity face plate.
5. Lift entire outer case from the unit.
6. Discharge the H.V. capacitor before carrying out any further work.
7. Do not operate the oven with the outer case removed.
CAUTION: DISCONNECT OVEN FROM POWER SUPPLY BEFORE
REMOVING OUTER CASE.
DISCHARGE THE HIGH VOLTAGE CAPACITOR
BEFORE TOUCHING ANY OVEN COMPONENTS OR
WIRING.
[3] POWER TRANSFORMER REMOVAL
1. Disconnect the power supply cord and remove outer case.
2. Open the oven door and block it open.
3. Discharge high voltage capacitor.
4. Disconnect the filament leads of power transformer from high volt-
age capacitor and the magnetron.
5. Disconnect the H.V. wire from the power transformer.
Microwave ovens contain circuitry capable of producing very high voltage and current, contact with following parts may result
in severe, possibly fatal, electric shock.
(Example)
High Voltage Capacitor, Power Transformer, Magnetron, High Voltage Rectifier Assembly, High Voltage Harness etc..
WARNING:
Avoid possible exposure to microwave energy. Please follow the instructions below before
operating the oven.
WARNING AGAINST HIGH VOLTAGE:
1. Disconnect the power supply cord.
2. Visually check the door and cavity face plate for damage
(dents, cracks, signs of arcing etc.).
Carry out any remedial work that is necessary before operat-
ing the oven.
Do not operate the oven if any of the following conditions exist;
1. Door does not close firmly.
2. Door hinge, support or latch hook is damaged.
3. The door gasket or seal is damaged.
4. The door is bent or warped.
5. There are defective parts in the door interlock system.
6. There are defective parts in the microwave generating
and transmission assembly.
7. There is visible damage to the oven.
Do not operate the oven:
1. Without the RF gasket (Magnetron).
2. If the wave guide or oven cavity are not intact.
3. If the door is not closed.
4. If the outer case (cabinet) is not fitted.
To prevent an electric shock, take the following precau-
tions.
1. Before wiring,
1) Disconnect the power supply cord.
2) Open the door block it open.
3) Discharge the high voltage capacitor and wait for 60
seconds.
2. Don't let the wire leads touch to the following parts;
1) High voltage parts:
Magnetron, High voltage transformer, High voltage
capacitor and High voltage rectifier assembly.
2) Hot parts:
Oven lamp, Magnetron, Power transformer and Oven
cavity.
WARNING FOR WIRING
3) Sharp edge:
Bottom plate, Oven cavity, Waveguide flange Chassis
supportand other metallic plate.
4) Movable parts (to prevent a fault)
Fan blade, Fan motor, Switch, Switch lever, and Antenna
motor
3. Do not catch the wire leads in the outer case cabinet.
4. Insert the positive lock connector until its pin is locked and
make sure that the wire leads do not come off even if the
wire leads are pulled.
5. To prevent an error function, connect the wire leads
correctly, referring to the Pictorial Diagram.