R-21HT-F
R-21JV-F
4
ITEM
DESCRIPTION
Power Requirements
120 Volts
14 Amperes
60 Hertz / Single phase, 3 wire grounded
Power Output
1000 watts (IEC 705 Test Procedure)
Operating frequency of 2450MHz
Case Dimensions
Width 20-1/2" (520mm)
Height 12-1/8" (309mm)
Depth 16"
(406mm)
Cooking Cavity Dimensions
Width 13-7/8" (353mm)
(1.0 Cubic Feet )
Height 8-1/8"
(207mm)
Depth 14-5/8" (370mm)
Control Complement
Touch Control System
Timer (0 - 99 min. 99 seconds)
Microwave Power for Variable Cooking
Repetition Rate;
P-HI ................................................... Full power throughout the cooking time
P-90 ...................................................................... approx. 90% of Full Power
P-80 ...................................................................... approx. 80% of Full Power
P-70 ...................................................................... approx. 70% of Full Power
P-60 ...................................................................... approx. 60% of Full Power
P-50 ...................................................................... approx. 50% of Full Power
P-40 ....................................................................... approx. 40% of Full Power
P-30 ....................................................................... approx. 30% of Full Power
P-20 ...................................................................... approx. 20% of Full Power
P-10 ....................................................................... approx. 10% of Full Power
P-0 ...................................................... No power throughout the cooking time
DOUBLE QUANTITY pad
EXPRESS DEFROST pad
Ten number pads
SELECTATIME pad
STOP/CLEAR pad
SELECTAPOWER pad
(R-21HT-F only)
START pad, SET pad
CHECK pad, SIGNAL pad
Oven Cavity Light
Yes
Safety Standard
UL Listed FCC Authorized
DHHS Rules, CFR, Title 21, Chapter 1, Subchapter J, NSF certified
SPECIFICATION
GENERAL INFORMATION
GROUNDING INSTRUCTIONS
This oven is equipped with a three prong grounding plug. It must be plugged into a wall receptacle that is properly installed and
grounded in accordance with the National Electrical Code and local codes and ordinances.
In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric
current.
WARNING: Improper use of the grounding plug can result in a risk of electric shock.
NOTE: Internal capacity is calculated by measuring
maximum width, depth and height.
Actual capacity for holding food is less.