MICROWAVE MEASUREMENT PROCEDURE

A. Requirements:

1) Microwave leakage limit (Power density limit): The power density of microwave radiation emitted by a microwave oven

should not exceed 1mW/cm

2

 at any point 5cm or more from the external surface of the oven, measured prior to acquisition

by a purchaser, and thereafter (through the useful life of the oven), 5 mW/cm

2

 at any point 5cm or more from the external

surface of the oven.

2) Safety interlock switches: Primary interlock switch shall prevent microwave radiation emission in excess of the

requirement as above mentioned, secondary interlock switch shall prevent microwave radiation emission in excess of
5 mW/cm

2

 at any point 5cm or more from the external surface of the oven.

B. Preparation for testing:
Before beginning the actual measurement of leakage, proceed as follows:
1) Make sure that the actual instrument is operating normally as specified in its instruction booklet.

Important:
Survey instruments that comply with the requirement for instrumentation as prescribed by the performance standard
for microwave ovens, 21 CFR 1030.10(c)(3)(i), must be used for testing.

2) Place the oven tray in the oven cavity.
3) Place the load of 275±15 ml (9.8 oz) of tap water initially at 20±5½C (68½F) in the center of the oven cavity.

The water container shall be a low form of 600 ml (20 oz) beaker with an inside diameter of approx. 8.5 cm (3-1/2 in.)
and made of an electrically nonconductive material such as glass or plastic.
The placing of this standard load in the oven is important not only to protect the oven, but also to insure that any leakage
is measured accurately.

4) Set the cooking control on Full Power Cooking Mode
5) Close the door and select a cook cycle of several minutes. If the water begins to boil before the survey is completed,

replace it with 275 ml of cool water.

C. Leakage test:

Closed-door leakage test (microwave measurement)
1) Grasp the probe of the survey instrument and hold it perpendicular to the gap between the door and the body of the oven.
2) Move the probe slowly, not faster than 1 in./sec. (2.5 cm/sec.) along the gap, watching for the maximum indication on

the meter.

3) Check for leakage at the door screen, sheet metal seams and other accessible positions where the continuity of the metal

has been breached (eg., around the switches, indicator, and vents).
While testing for leakage around the door pull the door away from the front of the oven as far as is permitted by the closed
latch assembly.

4) Measure carefully at the point of highest leakage and make sure that the highest leakage is no greater than 4mW/cm

2

,

and that the primary interlock switch and secondary interlock switch do turn the oven OFF before any door movement.

NOTE:  After servicing, record data on service invoice and microwave leakage report.

SERVICING FOR INVERTER UNIT

WARNING

This inverter unit contains circuitry capable of producing high voltage and high current. Contact with any part
of the high voltage will result in electrocution.

DO NOT ACCESS ANY PARTS OF INVERTER UNIT WITH POWER SUPPLY CONNECTED.
DO NOT OPERATE INVERTER UNIT ITSELF.

It is dangerous because this unit contains high voltage components.

Содержание R-2130JS

Страница 1: ... Voltage Rectifier and Heat sink etc and Magnetron High Voltage Harness etc S94M2R2130JS R 2130JS OVER THE RANGE MICROWAVE OVEN MODEL SUPPLEMENTAL SERVICE MANUAL SHARP CORPORATION This document has been published to be used for after sales service only The contents are subject to change without notice TABLE OF CONTENTS Page PRECAUTIONS TO BE OBSERVED BEFORE AND DURING SERVICING TO AVOID POSSIBLE E...

Страница 2: ...er the Microwave Measurement Procedure outlined in this service manual If microwave emissions level is in excess of the specified limit contact SHARP ELECTRONICS CORPORATION immediately 1 800 237 4277 If the unit operates with the door open service person should 1 tell the user not to operate the oven and 2 contact SHARP ELECTRONICS CORPORATION and Food and Drug Administration s Center for Devices...

Страница 3: ...ehighvoltagecapacitor waitfor60seconds 4 Disconnect the leads to the primary of the inverter unit 5 Ensure that these leads remain isolated from other components and oven chassis by using insulation tape 6 After that procedure reconnect the power supply cord When the testing is completed 1 Disconnect the power supply cord and then remove outer case 2 Open the door and block it open 3 Todischargehi...

Страница 4: ...acing of this standard load in the oven is important not only to protect the oven but also to insure that any leakage is measured accurately 4 Set the cooking control on Full Power Cooking Mode 5 Close the door and select a cook cycle of several minutes If the water begins to boil before the survey is completed replace it with 275 ml of cool water C Leakage test Closed door leakage test microwave ...

Страница 5: ...ges are not defective C The door packing is not damaged D The door is not deformed or warped E There is no other visible damage with the oven Servicing and repair work must be carried out only by trained service personnel DANGER Certain initial parts are intentionally not grounded and present a risk of electrical shock only during servicing Service personnel Do not contact the following parts whil...

Страница 6: ...Full power throughout the cooking time P 90 approx 90 of Full Power P 80 approx 80 of Full Power P 70 approx 70 of Full Power P 60 approx 60 of Full Power P 50 approx 50 of Full Power P 40 approx 40 of Full Power P 30 approx 30 of Full Power P 20 approx 20 of Full Power P 10 approx 10 of Full Power P 0 No power throughout the cooking time R 2130JS SENSOR CENTER pads MEAL TIME pads CUSTOM HELP pad ...

Страница 7: ...nding plug DO NOT UNDER ANY CIRCUMSTANCES CUT OR REMOVE THE GROUNDING PIN FROM THE PLUG The power supply cord and plug must be connected to a separate 120 Volt AC 60 Hz 15 Amp or more dedicated line using agroundedreceptacle ThereceptacleshouldbelocatedinsidethecabinetdirectlyabovetheMicrowaveOven Hoodsystem mounting location OVEN DIAGRAM 1 Oven door with see through window 2 Door hinges 3 Oven la...

Страница 8: ...ne touch cooking features such as MINUTE PLUS are disabled after three minutes when the oven is not in use These features are automatically enabled when the door is opened and closed or the STOP CLEAR pad is pressed R 2130JS ...

Страница 9: ...2 5 GCABUB131MRP0 M Outer case cabinet 1 BA 2 6 TMAPCB080MRR0 M Schematic diagram 1 AB 2 7 FANGKB019MRY0 M Hood lamp glass assembly 1 AY 2 8 PCOVPB111MRT0 M Base cover 1 AV 2 9 PCUSUB076MRP0 M Cabinet cushion 1 AA 2 10 LANG B007MRP0 M Bottom sash angle 1 AK CONTROL PANEL PARTS 3 1 CPWBFB102MRK0 M Control unit 1 BE 3 2 XEPSD30P08XS0 M Screw 3mm x 8mm 4 AA 3 3 LANG B005MRP0 M Key fixing angle 1 AG 3...

Страница 10: ...048MRF0 M Choke cover 1 AK 5 7 XCPSD40P08000 M Screw 4mm x 8mm 4 AA MISCELLANEOUS 6 1 CFZK B603MRK0 M Installation material assembly 1 AG 6 1 1 LBSHC0040MRE0 M Grommet 1 AC 6 1 2 LX BZ0195WRE0 M Toggle screw 4 AC 6 1 3 LX MZB001MRE0 M Cord holder 1 AB 6 1 4 XBRSD50P60000 M Screw 5mm x 60mm 2 AA 6 1 5 XOTSE40P12000 M Screw 4mm x 12mm 8 AA 6 1 6 XTSSD50P35000 M Screw 5mm x 35mm 6 AA 6 1 7 XWHSD50 16...

Страница 11: ... 7 7 1 6 4 9 7 5 7 9 7 1 6 9 4 6 1 10 1 10 1 11 2 3 4 14 7 9 7 6 7 9 7 9 4 5 7 3 7 2 6 16 7 2 6 16 7 7 4 2 4 2 4 10 4 3 7 7 7 7 1 14 7 7 1 5 4 30 1 8 1 7 4 29 4 19 2 5 4 16 4 13 4 31 6 8 2 9 4 18 7 4 4 4 4 4 7 4 7 2 7 4 6 13 4 17 7 2 7 2 2 4 6 13 2 2 6 12 4 27 4 26 4 26 4 22 4 8 7 8 4 15 6 8 1 4 4 28 2 6 6 10 7 2 7 2 7 2 4 7 7 2 7 3 7 2 7 6 2 8 7 2 7 2 7 2 2 7 2 10 7 8 7 8 4 24 1 8 4 25 4 23 1 4 1...

Страница 12: ... F G H A B C D E F G H 6 6 6 1 6 17 6 2 6 16 6 1 1 6 1 2 6 1 3 6 1 7 6 1 5 6 1 6 6 1 4 6 7 6 19 5 4 5 5 5 6 5 2 5 1 5 3 5 7 5 7 5 7 5 7 4 1 6 5 5 7 2 3 5 3 3 3 4 3 6 3 7 3 8 3 2 3 2 3 2 3 2 3 1 3 9 3 10 CONTROL PANEL PARTS MISCELLANEOUS DOOR PARTS ...

Страница 13: ... ACCESSORY PACK WRAP COVER DOOR PAD Non replaceable items DOOR PROTECTOR GREASE FILTER x 2 6 13 INSTALL MATERIAL ASSEMBLY 6 1 6 15 6 3 OPERATION MANUAL RECIPE CARD FOR R 2120JK W 6 4 SCALE PLATE x 2 6 17 Rack Bottom sash and 2 10 Bottom sash angle 6 2 2 4 TOP AND WALL TEMPLATE REAR CUSHION 6 11 EXHAUST DAMPER ASSEMBLY 6 14 ...

Страница 14: ...12 R 2130JS NOTES ...

Страница 15: ...13 R 2130JS NOTES ...

Страница 16: ...04 BY SHARP CORPORATION ALL RIGHTS RESERVED No part of this publication may be reproduced stored in retrieval systems or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without prior written permission of the publisher ...

Отзывы: