R-20A1(S)VN
10 – 2
[3] HIGH VOLTAGE TRANSFORMER REMOVAL
1. CARRY OUT 3D CHECKS.
2. Disconnect the wire leads (main wire harness and H.V. fuse) from
high voltage transformer.
magnetron.
high voltage capacitor.
5. Remove the two (2) screws holding the transformer to bottom plate
from below.
6. Remove the two (2) screws holding the transformer to bottom plate
from above.
7. Remove the transformer.
[4] HIGH VOLTAGE RECTIFIER ASSEMBLY, HIGH VOLTAGE FUSE AND HIGH VOLTAGE
CAPACITOR REMOVAL
To remove the components, proceed as follows.
1. CARRY OUT 3D CHECKS.
2. Disconnect the H.V. fuse from the high voltage transformer.
magnetron.
the H.V. capacitor.
5. Remove one (1) screw holding capacitor holder to the oven cavity
back plate.
6. Remove one (1) screw holding earth side terminal of high voltage
assembly from high voltage capacitor.
8. Disconnect the H.V. fuse from the high voltage capacitor.
free.
CAUTION: WHEN REPLACING HIGH VOLTAGE RECTIFIER
ASSEMBLY, ENSURE THAT THE CATHODE (EARTH)
CONNECTION IS SECURELY FIXED TO THE CAPACI-
TOR HOLDER WITH AN EARTHING SCREW.
CAUTION: DO NOT REPLACE ONLY HIGH VOLTAGE RECTIFIER.
WHEN REPLACING IT, REPLACE HIGH VOLTAGE REC-
TIFIER ASSEMBLY.
[5] MAGNETRON REMOVAL
1. REMOVAL
1. CARRY OUT 3D CHECKS.
2. Disconnect the wire leads from the magnetron.
3. Remove the two (2) screws holding the air duct to the oven cavity.
4. Release the air duct from the oven cavity.
5. Carefully remove the four (4) screws holding the magnetron to the
6. Lift up magnetron with care so that the magnetron antenna is not
hit by any metal object around antenna.
7. Now, the magnetron is free.
2. REINSTALLATION
screws.
2. Reinstall the air duct to the oven cavity with the two (2) screws.
3. Reconnect the wire leads to the magnetron. Refer to “PICTORIAL
DIAGRAM”.
4. Reinstall the outer case and check that the oven is operating prop-
erly.
CAUTION: WHEN REPLACING THE MAGNETRON, BE SURE THE
R.F. GASKET IS IN PLACE AND THE MAGNETRON
MOUNTING SCREWS ARE TIGHTENED SECURELY.
[6] POSITIVE LOCK CONNECTOR (NO-CASE TYPE) REMOVAL
1. CARRY OUT 3D CHECKS.
2. Push the lever of positive lock connector.
3. Pull down on the positive lock connector.
CAUTION: WHEN CONNECTING THE POSITIVE LOCK CONNEC-
TORS TO THE TERMINALS, CONNECT THE POSITIVE
LOCK
®
®
®
®
SO THAT THE LEVER FACES YOU.
Figure C-1. Positive lock
®
connector
Terminal
Push
Pull down
1
2
Lever
Positive lock¨
connector