35
R-1880LS/LST
18
P50
OUT
Convection motor driving signal.
To turn on and off shut-off relay(RY7). "L" level during
CONVECTION; "H" level otherwise.
19
P47
OUT
Hood lamp driving signal.
To turn on and off relay(RY8). "L" level: During Hood
lamp ON. "H" level: During Hood lamp OFF.
0
P46
OUT
Hood motor driving signal.
To turn on and off relay(RY9). "L" level: During Hood
motor ON. "H" level: During Hood motor OFF.
1
P45
OUT
Hood motor high / low driving signal.
To turn on and off relay(RY10). "L" level: During Hood
motor high. "H" level: During Hood motor low.
P44
OUT
Timing signal output terminal for temperature measurement(OVEN).
"L" level (GND): Thermistor OPEN timing.
"H" level (-5V): Temperature measuring timing. (Convection cooking)
3
P43
OUT
Signal to sound buzzer.
A: key touch sound.
B: Completion sound.
C: When the temperature of the oven cavity reaches the
preset temperature in the preheating mode, or when the
preheating hold time (30 minutes) is elapsed.
4
P4
IN
Input signal which communicates the damper open/close information to LSI.
Damper opened; "L" level signal(0V:GND).
Damper closed; "H" level signal(-5V).
5
INT1
IN
Signal to synchronize LSI with commercial power source freqency.
This is the basic timing for all real time processing of LSI.
6
P40
IN
Connected to VC.
7
RST
IN
Auto clear terminal.
Signal is input to reset the LSI to the initial state when power is applied. Temporarily set to "L"
level the moment power is applied, at this time the LSI is reset. Thereafter set at "H" level.
8
P71
OUT
Magnetron high-voltage circuit driving signal.
To turn on and off the cook relay(RY).
In P-HI operation, the signals holds "L"
level during microwave cooking and
"H" level while not cooking. In other
cooking modes (P-90,P-80,P-70,P-
60,P-50,P-40,P-30,P-0,P-10,P-0) the
signal turns to "H" level and "L" level
in repetition according to the power
level.
9
P70
OUT
Heating element driving signal.
To turn on and off shut-off relay(RY3). "L" level during convection cooking; "H" level other-
wise. During convection cooking, the signal becomes
"H" level when the temperature of the oven cavity exceeds
the predetermined temperature.
30
XIN
IN
Internal clock oscillation frequency setting input.
The internal clock frequency is set by inserting the ceramic filter oscillation circuit with respect
to XOUT terminal.
31
XOUT
OUT
Internal clock oscillation frequency control output.
Pin No.
Signal
I/O
Description
VARI-MODE
ON TIME
OFF TIME
P-HI (100% power)
3 sec.
0 sec.
P-90 (approx. 90% power)
30 sec.
sec.
P-80 (approx. 80% power)
6 sec.
6 sec.
P-70 (approx. 70% power)
4 sec.
8 sec.
P-60 (approx. 60% power)
sec.
10 sec.
P-50 (approx. 50% power)
18 sec.
14 sec.
P-40 (approx. 40% power)
16 sec.
16 sec.
P-30 (approx. 30% power)
1 sec.
0 sec.
P-0 (approx. 0% power)
8 sec.
4 sec.
P-10 (approx. 10% power)
6 sec.
6 sec.
P-0 (0% power)
0 sec.
3 sec.
ON
OFF
During
cooking
L
GND
H.
(Convection)
ON
OFF
H : GND
L
ON
OFF
H : GND
L
ON
OFF
H : GND
L
A
B
C
H: GND
L
0.1 sec
2 sec
1 sec
1 sec
H : GND
L (-5V)
16.7 msec
ON
OFF
During
cooking
L
GND
H.
(Convection)