32
R-1850
R-1851
1. Remove the three (3) screws holding the base cover to
the oven cavity
2. Remove the base cover from the oven cavity by pulling
down and moving to the left slightly.
3. Disconnect the wire leads from the turntable motor.
4. Remove two (2) screws holding turntable motor to the
4. Lift the oven lamp cover up.
5. Now, the oven lamp and the socket are found.
6. Screw the oven lamp off from the lamp socket.
7. Now, the oven lamp is free.
NOTE: HOT (YELLOW) WIRE MUST BE CONNECTED
TO THE TERMINAL WITH BLUE MARKING ON
LAMP SOCKET.
3. Install the fan duct assembly to the oven cavity with the
one (1) screw.
4. Install the magnetron duct to the fan duct and oven
cavity.
5. Connect the wire leads to the fan motor, referring to the
pictorial diagram.
6. Reinstall the released snap bands of the main harness
A to the fan duct and nearest the fan duct.
7. Refer to procedure of "HOOD FAN MOTOR, HOOD
EXHAUST DUCT, OVEN LAMP SOCKET AND AH
SENSOR REMOVAL" and "Unit Mounting Screw and
Hood Intake Duct R Removal" and "Outer case Removal".
And reverse their procedure.
And install the hood intake duct R, hood exhaust duct
and outer case.
Shaft
Table
Center of
bracket
TURNTABLE MOTOR AND COUPLING REMOVAL
oven cavity.
5. Now the turntable motor is free.
6. Pull the coupling out of the turntable motor packing which
is installed on the oven cavity floor.
7. Now the coupling is free.
1. Unplug the oven from power outlet and remove the oven
from wall and remove outer case. (Refer to procedure of
"Removal of Oven from Wall" and Outer case Removal")
2. Remove the hood fan motor and the hood exhaust duct
from the oven cavity, referring to the procedure of "
HOOD FAN MOTOR, HOOD EXHAUST DUCT, OVEN
LAMP SOCKET AND AH SENSOR REMOVAL".
3. Disconnect the wire leads from the stirrer motor.
STIRRER MOTOR REMOVAL
4. Remove the two (2) screws holding the stirrer motor to
the waveguide of the oven cavity.
5. Remove the stirrer motor from the waveguide.
6. Now, the stirrer motor is free.
7. When install the stirrer motor, the shaft of stirrer motor
must be inserted to the stirrer fan shaft. Refer to the
procedure of "STIRRER COVER AND STIRRER FAN
INSTALLATION".
1. Insert the shaft of stirrer fan to the shaft of stirrer motor.
2. Hold the stirrer fan not to come out from the shaft of
stirrer motor.
3. Insert the cutout of stirrer cover to the tabs on the ceiling.
4. Put the stirrer fan on the stirrer cover to match the stirrer
fan shaft to the center of the stirrer support.
5. Hold the stirrer cover to the oven cavity with the two (2)
screws.
STIRRER COVER AND STIRRER FAN INSTALLATION
Shaft
Stirrer fan
Stirrer
support
Stirrer
cover
Screws
1. Unplug the oven from power outlet.
2. Remove one (1) screw holding the hood exhaust louver
to oven cavity front flange.
3. Remove the hood exhaust louver from the oven by
pushing the right and left tabs of the hood exhaust louver.
(Refer to procedure of "HOOD EXHAUST LOUVER
REMOVAL")
OVEN LAMP REMOVAL
1. Unplug the oven from power outlet.
2. Remove one (1) screw holding the hood exhaust louver
to oven cavity front flange.
3. Remove the hood exhaust louver from the oven by
pushing the right and left tabs of the hood exhaust louver.
CONTROL PANEL ASSEMBLY, CONTROL UNIT AND KEY UNIT REMOVAL
(Refer to procedure of "HOOD EXHAUST LOUVER
REMOVAL")
4. Open the oven door.
5. Remove one (1) screw holding the control panel to the
oven cavity front face plate.